Correction of low levels of astigmatism.

PURPOSE: To reevaluate the analysis of the correction of astigmatism.

SETTING: Academia, industry, and private practice.

DESIGN: Evaluation of diagnostic test or technology.

METHODS: Astigmatic refractive surgery outcomes are based on vector methods, including the correction index (also known as the correction ratio), which is the ratio of the surgically induced astigmatism to the target induced astigmatism (TIA). Mean correction indices substantially greater than 1 have been reported for astigmatic corrections less than 1.00 diopter (D) and as representing systematic overcorrection. We hypothesize that this reflects a limitation of the correction index rather than systematic flaws in treatments. The theoretical mathematic behavior of the correction index was analyzed, accounting for variability in astigmatism measurement. Then, the impact of cylinder measurement variability on the mean correction index was modeled. A Monte Carlo simulation was performed and calculated 10 000 values of correction index for various values of TIA. Finally, correction indices from published and unpublished studies of refractive lasers were compared with the simulations.

RESULTS: The mean correction index is always greater than 1 for the case of a perfect refractive correction; however, for astigmatic corrections less than 1.00 D, the mean correction index increases sharply because the measurement variability is similar in magnitude to TIA. Almost all previous studies show the predicted increase in the correction index for low astigmatic corrections.

CONCLUSION: The correction index is a useful vector-based metric for the evaluation of refractive procedures, but mean values greater than 1 should be anticipated for lower astigmatic treatments and do not necessarily represent systematic overcorrection.

FINANCIAL DISCLOSURE: Dr. Bullimore is a consultant to Alcon Surgical, Inc., Carl Zeiss Meditec AG, Digital Vision Systems, Essilor, Innovega, Inc., and Paragon Vision Sciences, Inc. Dr. Spooner is a consultant to Alcon Surgical, Inc., Carl Zeiss Meditec AG, Digital Vision Systems, Thru-Focus Optics LLC, and i2eyediagnostics, Ltd. Dr. Dishler is a consultant to Carl Zeiss Meditec AG and Revision Optics, Inc. Dr. Sluyterman is an employee of Carl Zeiss Meditec AG.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app