BACKGROUND: Nasoenteral tube feeding is frequently required in hospitalized patients to either prevent or treat malnutrition, but data on the optimal strategy of tube placement are lacking.

OBJECTIVE: To compare the efficacy and safety of bedside electromagnetic (EM)-guided, endoscopic, and fluoroscopic placement of nasoenteral feeding tubes in adults.

DESIGN: Systematic review of the literature.

PATIENTS: Adult hospitalized patients requiring nasoenteral feeding.

INTERVENTIONS: EM-guided, endoscopic, and/or fluoroscopic nasoenteral feeding tube placement.

MAIN OUTCOME MEASUREMENTS: Success rate of tube placement and procedure- or tube-related adverse events.

RESULTS: Of 354 screened articles, 28 studies were included. Data on 4056 patients undergoing EM-guided (n = 2921), endoscopic (n = 730), and/or fluoroscopic (n = 405) nasoenteral feeding tube placement were extracted. Tube placement was successful in 3202 of 3789 (85%) EM-guided procedures compared with 706 of 793 (89%) endoscopic and 413 of 446 (93%) fluoroscopic procedures. Reinsertion rates were similar for EM-guidance (270 of 1279 [21%] patients) and endoscopy (64 of 394 [16%] patients) or fluoroscopy (10 of 38 [26%] patients). The mean (standard deviation) procedure time was shortest with EM-guided placement (13.4 [12.9] minutes), followed by endoscopy and fluoroscopy (14.9 [8.7] and 16.2 [23.6] minutes, respectively). Procedure-related adverse events were infrequent (0.4%, 4%, and 3%, respectively) and included mainly epistaxis. The tube-related adverse event rate was lowest in the EM-guided group (36 of 242 [15%] patients), followed by fluoroscopy (40 of 191 [21%] patients) and endoscopy (115 of 384 [30%] patients) and included mainly dislodgment and blockage of the tube.

LIMITATIONS: Heterogeneity and limited methodological quality of the included studies.

CONCLUSION: Bedside EM-guided placement of nasoenteral feeding tubes appears to be as safe and effective as fluoroscopic or endoscopic placement. EM-guided tube placement by nurses may be preferred over more costly procedures performed by endoscopists or radiologists, but randomized studies are lacking.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app