Renal dysfunction and clinical outcomes of patients undergoing ICD and CRTD implantation: data from the Israeli ICD registry.

BACKGROUND: Implantable cardioverter defibrillators (ICDs) and cardiac resynchronization therapy (CRT) reduce mortality in patients with heart failure (HF) and left ventricular dysfunction. However, their efficacy in patients with chronic kidney disease (CKD) is controversial.

OBJECTIVE: We examined the association between renal dysfunction and clinical outcomes in patients undergoing ICD and CRT defibrillator (CRTD) implantation.

METHODS: Data were collected from the Israeli ICD registry. Estimated glomerular filtration rate (eGFR) at implantation was assessed using the modification of diet in renal disease formula. Primary outcome was all-cause mortality. Secondary outcomes included the composite endpoints of death or HF and death or ventricular arrhythmias (ventricular tachycardia/ventricular fibrillation [VT/VF]); any hospitalizations; first appropriate and inappropriate ICD therapy.

RESULTS: During the study period (July 2010-November 2012), 2,811 patients were implanted with ICD or CRTD. One-year follow-up data were available for 730 ICD patients and 453 CRTD patients. Patients with eGFR < 30 mL/minute/1.73 m(2) (n = 54, 4.6%) were older, had a higher prevalence of diabetes, hypertension, or ischemic heart disease. eGFR <30 mL/minute/1.73 m(2) was associated with increased mortality risk in ICD (HR 5.4; 95% CI 1.5-19.2), but not in CRTD patients (HR 0.9; 95% CI 0.1-7.5). Renal dysfunction was associated with the composite endpoints of death or HF and death or VT/VF in ICD, but not in CRTD patients. Mean eGFR during follow-up decreased by 8.0 ± 4.3 mL/minute/1.73 m(2) in ICD patients (P = 0.06) and by 1.8 ± 1.3 mL/minute/1.73 m(2) in patients with CRTD (P = 0.2).

CONCLUSION: Based on this retrospective analysis, CKD is associated with adverse prognosis after ICD implantation, but not after CRTD implantation. GFR decreased in patients with ICD, but not in CRTD patients.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app