keyword
https://read.qxmd.com/read/38431539/sbrt-sg-01-final-results-of-a-prospective-multicenter-study-on-stereotactic-body-radiotherapy-for-liver-metastases
#21
JOURNAL ARTICLE
María-Carmen Rubio Rodríguez, Xin Chen-Zhao, Ovidio Hernando, Sonia Flamarique, Pedro Fernández-Letón, Maider Campo, Mercedes López, Maitane Rodríguez, Daniel Zucca, Daniel Martínez, Emilio Sánchez-Saugar, Fernando Mañeru, Juan García Ruiz-Zorrilla, Paz García de Acilu, Jeannette Valero, Angel Montero, Raquel Ciérvide, Beatriz Alvarez, Mariola García-Aranda, Rosa Alonso, Miguel Angel de la Casa, Leyre Alonso, Mónica Nuñez, Jaime Martí, Fernando Arias
OBJECTIVE: This study aimed to assess the efficacy and tolerability of stereotactic body radiation therapy (SBRT) for the treatment of liver metastases. METHODS: Patients with up to 5 liver metastases were enrolled in this prospective multicenter study and underwent SBRT. Efficacy outcomes included in-field local control (LC), progression-free survival (PFS), and overall survival (OS). Acute and late toxicities were evaluated using CTCAE v.4.0. RESULTS: A total of 52 patients with 105 liver metastases were treated between 2015 and 2018...
March 2, 2024: Clinical & Translational Oncology
https://read.qxmd.com/read/38406888/paediatric-cbct-protocols-for-image-guided-radiotherapy-outcome-of-a-survey-across-siop-europe-affiliated-countries-and-literature-review
#22
JOURNAL ARTICLE
Daniella Elisabet Østergaard, Abigail Bryce-Atkinson, Mikkel Skaarup, Bob Smulders, Lucy Siew Chen Davies, Gillian Whitfield, Geert O Janssens, Lisa Lyngsie Hjalgrim, Ivan Vogelius Richter, Marcel van Herk, Marianne Aznar, Maja Vestmø Maraldo
BACKGROUND: Implementation of daily cone-beam CT (CBCT) into clinical practice in paediatric image-guided radiotherapy (IGRT) lags behind compared to adults. Surveys report wide variation in practice for paediatric IGRT and technical information remains unreported. In this study we report on technical settings from applied paediatric CBCT protocols and review the literature for paediatric CBCT protocols. METHODS: From September to October 2022, a survey was conducted among 246 SIOPE-affiliated centres across 35 countries...
January 2024: Radiotherapy and Oncology
https://read.qxmd.com/read/38403521/the-application-of-virtual-environment-radiotherapy-for-rtt-training-a-scoping-review
#23
REVIEW
Andrea Lastrucci, Claudio Votta, Eva Serventi, Patrizia Cornacchione, Simona Francioni, Yannick Wandael, Cinzia Talamonti, Renzo Ricci
BACKGROUND: Virtual Environment Radiotherapy Training (VERT) is a virtual tool used in radiotherapy with a dual purpose: patient education and student training. This scoping review aims to identify the applications of VERT to acquire new skills in specific activities of Radiation Therapists (RTTs) clinical practice and education as reported in the literature. This scoping review will identify any gaps in this field and provide suggestions for future research. METHODS: In accordance with Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) extension for scoping reviews and Arskey and O'Malley framework, an electronic search was conducted to retrieve complete original studies, reporting the use and implementation of VERT for teaching skills to RTTs...
February 24, 2024: Journal of Medical Imaging and Radiation Sciences
https://read.qxmd.com/read/38392066/electromagnetic-transmitter-based-prostate-gating-for-dose-escalated-linac-based-stereotactic-body-radiation-therapy-an-evaluation-of-intrafraction-motion
#24
JOURNAL ARTICLE
Berardino De Bari, Geoffroy Guibert, Sabrine Slimani, Yanes Bashar, Terence Risse, Nicole Guisolan, Juliane Trouillot, Jonathan Abel, Patrick Weber
BACKGROUND: Stereotactic Body Radiotherapy (SBRT) is as a standard treatment for prostate cancer (PCa). Tight margins and high dose gradients are needed, and the precise localization of the target is mandatory. Our retrospective study reports our experience regarding the evaluation of intrafraction prostate motion during LINAC-based SBRT evaluated with a novel electromagnetic (EM) tracking device. This device consists of an integrated Foley catheter with a transmitter connected to a receiver placed on the treatment table...
February 9, 2024: Current Oncology
https://read.qxmd.com/read/38392056/quality-of-life-longitudinal-evaluation-in-prostate-cancer-patients-from-radiotherapy-start-to-5-years-after-imrt-igrt
#25
JOURNAL ARTICLE
Angelo Maggio, Tiziana Rancati, Marco Gatti, Domenico Cante, Barbara Avuzzi, Cinzia Bianconi, Fabio Badenchini, Bruno Farina, Paolo Ferrari, Tommaso Giandini, Giuseppe Girelli, Valeria Landoni, Alessandro Magli, Eugenia Moretti, Edoardo Petrucci, Paolo Salmoiraghi, Giuseppe Sanguineti, Elisa Villa, Justyna Magdalena Waskiewicz, Alessia Guarneri, Riccardo Valdagni, Claudio Fiorino, Cesare Cozzarini
PURPOSE: The purpose of this study is to study the evolution of quality of life (QoL) in the first 5 years following Intensity-modulated radiation therapy (IMRT) for prostate cancer (PCa) and to determine possible associations with clinical/treatment data. MATERIAL AND METHODS: Patients were enrolled in a prospective multicentre observational trial in 2010-2014 and treated with conventional (74-80 Gy, 1.8-2 Gy/fr) or moderately hypofractionated IMRT (65-75.2 Gy, 2...
February 1, 2024: Current Oncology
https://read.qxmd.com/read/38382110/automated-detection-of-vertebral-body-misalignments-in-orthogonal-kv-and-mv-guided-radiotherapy-application-to-a-comprehensive-retrospective-dataset
#26
JOURNAL ARTICLE
John A Charters, Dishane Luximon, Rachel Petragallo, Jack Neylon, Daniel A Low, James M Lamb
OBJECTIVE: In image-guided radiotherapy (IGRT), off-by-one vertebral body misalignments are rare but potentially catastrophic. In this study, an automated method to detect such misalignments with IGRT radiographs was investigated using densely-connected convolutional networks (DenseNets) for applications towards real-time error prevention and retrospective error auditing. APPROACH: A total of 4213 images acquired from 527 radiotherapy patients aligned with planar kV or MV radiographs were used to develop and test error-detection software modules...
February 21, 2024: Biomedical Physics & Engineering Express
https://read.qxmd.com/read/38369991/virtual-unenhanced-dual-energy-computed-tomography-for-photon-radiotherapy-the-effect-on-dose-distribution-and-cone-beam-computed-tomography-based-position-verification
#27
JOURNAL ARTICLE
Maryam Afifah, Marloes C Bulthuis, Karin N Goudschaal, Jolanda M Verbeek-Spijkerman, Tezontl S Rosario, Duncan den Boer, Karel A Hinnen, Arjan Bel, Zdenko van Kesteren
BACKGROUND AND PURPOSE: Virtual Unenhanced images (VUE) from contrast-enhanced dual-energy computed tomography (DECT) eliminate manual suppression of contrast-enhanced structures (CES) or pre-contrast scans. CT intensity decreases in high-density structures outside the CES following VUE algorithm application. This study assesses VUE's impact on the radiotherapy workflow of gynecological tumors, comparing dose distribution and cone-beam CT-based (CBCT) position verification to contrast-enhanced CT (CECT) images...
January 2024: Physics and Imaging in Radiation Oncology
https://read.qxmd.com/read/38334889/the-effects-of-mega-voltage-ct-scan-parameters-on-offline-adaptive-radiation-therapy
#28
JOURNAL ARTICLE
Kento Hoshida, Ayumu Ohishi, Asumi Mizoguchi, Sunao Ohkura, Hidemichi Kawata
TomoTherapy involves image-guided radiation therapy (IGRT) using Mega-voltage CT (MVCT) for each treatment session. The acquired MVCT images can be utilized for the retrospective assessment of dose distribution. The TomoTherapy provides 18 distinct imaging conditions that can be selected based on a combination of algorithms, acquisition pitch, and slice interval. We investigated the accuracy of dose calculation and deformable image registration (DIR) depending on MVCT scan parameters and their effects on adaptive radiation therapy (ART)...
March 2024: Radiological Physics and Technology
https://read.qxmd.com/read/38320884/performance-assessment-of-the-surface-guided-radiation-therapy-system-varian-identify
#29
JOURNAL ARTICLE
Oğuzhan Ayrancıoğlu, Ceren Ayrancıoğlu, Şerife Ceren Arıkan, Lütfiye Zümre Arıcan Alıcıkuş
Image-guided radiotherapy (IGRT) systems using ionizing radiation may increase the risk of secondary cancer and normal tissue toxicity due to additional radiation exposure caused by large field sizes or repeated scans during X-ray imaging. As an alternative to these modalities, surface-guided radiotherapy (SGRT) systems which do not employ ionizing radiation have been developed. This study presents a comprehensive performance evaluation of the Varian Identify SGRT system by using an anthropomorphic Alderson Rando phantom in three different aspects: (a) the accuracy and reproducibility of the system in different regions of interest (ROI) for varying couch displacements, (b) the setup accuracy of the system for patient positioning based on different computed tomography (CT) slice thicknesses, and (c) the potential influence of obstructing SGRT cameras by the gantry on the system's overall accuracy and reproducibility...
February 5, 2024: Medical Dosimetry: Official Journal of the American Association of Medical Dosimetrists
https://read.qxmd.com/read/38320336/energy-guided-diffusion-model-for-cbct-to-ct-synthesis
#30
JOURNAL ARTICLE
Linjie Fu, Xia Li, Xiuding Cai, Dong Miao, Yu Yao, Yali Shen
Cone Beam Computed Tomography (CBCT) plays a crucial role in Image-Guided Radiation Therapy (IGRT), providing essential assurance of accuracy in radiation treatment by monitoring changes in anatomical structures during the treatment process. However, CBCT images often face interference from scatter noise and artifacts, posing a significant challenge when relying solely on CBCT for precise dose calculation and accurate tissue localization. There is an urgent need to enhance the quality of CBCT images, enabling a more practical application in IGRT...
February 2, 2024: Computerized Medical Imaging and Graphics: the Official Journal of the Computerized Medical Imaging Society
https://read.qxmd.com/read/38304111/intrafraction-motion-and-margin-assessment-for-ethos-online-adaptive-radiotherapy-treatments-of-the-prostate-and-seminal-vesicles
#31
JOURNAL ARTICLE
Mikel Byrne, Amy Yuen Meei Teh, Ben Archibald-Heeren, Yunfei Hu, James Rijken, Suhuai Luo, Trent Aland, Peter Greer
PURPOSE: Online adaptive radiation therapy (OART) uses daily imaging to identify changes in the patient's anatomy and generate a new treatment plan adapted to these changes for each fraction. The aim of this study was to determine the intrafraction motion and planning target volume (PTV) margins required for an OART workflow on the Varian Ethos system. METHODS AND MATERIALS: Sixty-five fractions from 13 previously treated OART patients were analyzed for this retrospective study...
March 2024: Advances in Radiation Oncology
https://read.qxmd.com/read/38298751/use-of-the-40-gene-expression-profile-40-gep-test-in-medicare-eligible-patients-diagnosed-with-cutaneous-squamous-cell-carcinoma-cscc-to-guide-adjuvant-radiation-therapy-art-decisions-leads-to-a-significant-reduction-in-healthcare-costs
#32
JOURNAL ARTICLE
Ally-Khan Somani, Sherrif F Ibrahim, Michael Tassavor, Jane Yoo, Aaron S Farberg
OBJECTIVE: Adjuvant radiation therapy (ART) is often recommended for high-risk cSCC patients but carries significant costs and risks. This study aims to determine if utilizing the 40-GEP test to guide ART can reduce healthcare costs in cSCC management. METHODS: Medical claims data with new diagnoses of cSCC for the 12 months ending June 2022 in the Medicare (≥65 years) population (source: IQVIA claims database) were obtained and normalized to the general population for missingness...
January 2024: Journal of Clinical and Aesthetic Dermatology
https://read.qxmd.com/read/38292891/clinical-experience-of-intrafractional-motion-monitoring-of-patients-under-head-and-neck-radiation-therapy-using-exactrac-dynamic-system
#33
JOURNAL ARTICLE
Vivian U Y Chow, Michael L M Cheung, Monica W K Kan, Anthony T C Chan
PURPOSE: The combination of surface-guided radiation therapy (SGRT) and image-guided radiation therapy (IGRT) can provide complementary information of patient positioning throughout treatments. The ExacTrac Dynamic (EXTD) system is a combined SGRT and IGRT system that can provide real-time motion detection via optical surface and thermal tracking during treatment delivery, with stereoscopic x-ray for positional verification. The purpose of this study was to examine the performance of EXTD for intrafractional motion monitoring using real clinical cases...
March 2024: Advances in Radiation Oncology
https://read.qxmd.com/read/38268200/verification-of-surface-guided-radiation-therapy-sgrt-alignment-for-proton-breast-and-chest-wall-patients-by-comparison-to-ct-on-rails-and-kv-2d-alignment
#34
JOURNAL ARTICLE
Hui Zhao, Vikren Sarkar, Sara St James, Adam Paxton, Fan-Chi Frances Su, Ryan G Price, Christian Dial, Matthew Poppe, David Gaffney, Bill Salter
BACKGROUND: Surface-guided radiation therapy (SGRT) systems have been widely installed and utilized on linear accelerators. However, the use of SGRT with proton therapy is still a newly developing field, and published reports are currently very limited. PURPOSE: To assess the clinical application and alignment agreement of SGRT with CT-on-rails (CTOR) and kV-2D image-guided radiation therapy (IGRT) for breast treatment using proton therapy. METHODS: Four patients receiving breast or chest wall treatment with proton therapy were the subjects of this study...
January 24, 2024: Journal of Applied Clinical Medical Physics
https://read.qxmd.com/read/38266298/respiratory-motion-modelling-for-mr-guided-lung-cancer-radiotherapy-model-development-and-geometric-accuracy-evaluation
#35
JOURNAL ARTICLE
Björn Eiben, Jenny Bertholet, Elena Huong Tran, Andreas Wetscherek, Anna-Maria Shiarli, Simeon Nill, Uwe Oelfke, Jamie R McClelland
Respiratory motion of lung tumours and adjacent structures is challenging for radiotherapy. Online MR-imaging cannot currently provide real-time volumetric information of the moving patient anatomy, therefore limiting precise dose delivery, delivered dose reconstruction, and downstream adaptation methods. 

Approach: We tailor a respiratory motion modelling framework towards an MR-Linac workflow to estimate the time-resolved 4D motion from real-time data. We develop a multi-slice acquisition scheme which acquires thick, overlapping 2D motion-slices in different locations and orientations, interleaved with 2D surrogate-slices from a fixed location...
January 24, 2024: Physics in Medicine and Biology
https://read.qxmd.com/read/38261432/volumetric-and-geometric-changes-in-the-parotid-glands-and-target-volume-during-image-guided-radiotherapy-for-locally-advanced-oropharyngeal-cancers
#36
JOURNAL ARTICLE
Sagar Gayakwad, Ashwini Budrukkar, Vedang Murthy, Sarbani G Laskar, Ritu Raj Upreti, Udita Upreti, Tejpal Gupta, Jai Prakash Agarwal
PURPOSE: This study aimed to evaluate the volumetric and geometric changes in the parotid glands and target volume during image-guided radiotherapy (IGRT) for locally advanced oropharyngeal cancers. MATERIALS AND METHODS: Twenty patients receiving radiotherapy using IGRT at a dose of 70 Gy/35 fractions/7 weeks for locally advanced oropharyngeal cancers were accrued. Radiotherapy planning computed tomography (CT) scans were performed at pre-radiotherapy (RT), 20, 40, and 60 Gy for each patient...
January 22, 2024: Journal of Cancer Research and Therapeutics
https://read.qxmd.com/read/38254760/mr-linac-a-new-partner-in-radiation-oncology-current-landscape
#37
REVIEW
Abrahams Ocanto, Lisselott Torres, Miguel Montijano, Diego Rincón, Castalia Fernández, Beatriz Sevilla, Daniela Gonsalves, Macarena Teja, Marcos Guijarro, Luis Glaría, Raúl Hernánz, Juan Zafra-Martin, Noelia Sanmamed, Amar Kishan, Filippo Alongi, Drew Moghanaki, Himanshu Nagar, Felipe Couñago
Technological advances in radiation oncology are oriented towards improving treatment precision and tumor control. Among these advances, magnetic-resonance-image-guided radiation therapy (MRgRT) stands out, with technological advances to deliver targeted treatments adapted to a tumor's anatomy on the day while minimizing incidental exposure to organs at risk, offering an unprecedented therapeutic advantage compared to X-ray-based IGRT delivery systems. This new technology changes the traditional workflow in radiation oncology and requires an evolution in team coordination to administer more precise treatments...
January 8, 2024: Cancers
https://read.qxmd.com/read/38246849/improved-dosimetry-with-daily-online-adaptive-radiotherapy-for-cervical-cancer-waltzing-the-pear
#38
JOURNAL ARTICLE
A Yen, X Zhong, M-H Lin, C Nwachukwu, K Albuquerque, B Hrycushko
AIMS: Standard of care radiotherapy for locally advanced cervical cancer includes large margins to ensure the uterocervix remains within the treatment fields over the course of treatment. Daily online cone-beam adaptive radiotherapy corrects for interfractional changes by adjusting the plan to match the target position during each treatment session, thus allowing for significantly reduced clinical target volume (CTV) to planning target volume (PTV) margins. We hypothesise that reduced margins from daily online adaptive radiotherapy will reduce organ at risk dose without compromising target coverage...
January 17, 2024: Clinical Oncology: a Journal of the Royal College of Radiologists
https://read.qxmd.com/read/38241802/pseudo-medical-image-guided-technology-based-on-cbct-only-mode-in-esophageal-cancer-radiotherapy
#39
JOURNAL ARTICLE
Hongfei Sun, Zhi Yang, Jiarui Zhu, Jie Li, Jie Gong, Liting Chen, Zhongfei Wang, Yutian Yin, Ge Ren, Jing Cai, Lina Zhao
Purpose To minimize the various errors introduced by image-guided radiotherapy (IGRT) in the application of esophageal cancer treatment, this study proposes a novel technique based on the 'CBCT-only' mode of pseudo-medical image guidance. Methods The framework of this technology consists of two pseudo-medical image synthesis models in the CBCT→CT and the CT→PET direction. The former utilizes a dual-domain parallel deep learning model called AWM-PNet, which incorporates attention waning mechanisms...
January 5, 2024: Computer Methods and Programs in Biomedicine
https://read.qxmd.com/read/38223024/deep-learning-based-projection-synthesis-for-low-dose-cone-beam-computed-tomography-imaging-in-image-guided-radiotherapy
#40
JOURNAL ARTICLE
Xuzhi Zhao, Yi Du, Haizhen Yue, Ruoxi Wang, Shun Zhou, Hao Wu, Wei Wang, Yahui Peng
BACKGROUND: The imaging dose of cone-beam computed tomography (CBCT) in image-guided radiotherapy (IGRT) poses adverse effects on patient health. To improve the quality of sparse-view low-dose CBCT images, a projection synthesis convolutional neural network (SynCNN) model is proposed. METHODS: Included in this retrospective, single-center study were 223 patients diagnosed with brain tumours from Beijing Cancer Hospital. The proposed SynCNN model estimated two pairs of orthogonally direction-separable spatial kernels to synthesize the missing projection in between the input neighboring sparse-view projections via local convolution operations...
January 3, 2024: Quantitative Imaging in Medicine and Surgery
keyword
keyword
12351
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.