Add like
Add dislike
Add to saved papers

Automated Identification of Different Severity Levels of Diabetic Retinopathy Using a Handheld Fundus Camera and Single-Image Protocol.

PURPOSE: To evaluate the performance of artificial intelligence (AI) systems embedded in a mobile, handheld retinal camera, with a single retinal image protocol, in detecting both diabetic retinopathy (DR) and more-than-mild diabetic retinopathy (mtmDR).

DESIGN: Multicenter cross-sectional diagnostic study, conducted at 3 diabetes care and eye care facilities.

PARTICIPANTS: A total of 327 individuals with diabetes mellitus (type 1 or type 2) underwent a retinal imaging protocol enabling expert reading and automated analysis.

METHODS: Participants underwent fundus photographs using a portable retinal camera (Phelcom Eyer). The captured images were automatically analyzed by deep learning algorithms retinal alteration score (RAS) and diabetic retinopathy alteration score (DRAS), consisting of convolutional neural networks trained on EyePACS data sets and fine-tuned using data sets of portable device fundus images. The ground truth was the classification of DR corresponding to adjudicated expert reading, performed by 3 certified ophthalmologists.

MAIN OUTCOME MEASURES: Primary outcome measures included the sensitivity and specificity of the AI system in detecting DR and/or mtmDR using a single-field, macula-centered fundus photograph for each eye, compared with a rigorous clinical reference standard comprising the reading center grading of 2-field imaging protocol using the International Classification of Diabetic Retinopathy severity scale.

RESULTS: Of 327 analyzed patients (mean age, 57.0 ± 16.8 years; mean diabetes duration, 16.3 ± 9.7 years), 307 completed the study protocol. Sensitivity and specificity of the AI system were high in detecting any DR with DRAS (sensitivity, 90.48% [95% confidence interval (CI), 84.99%-94.46%]; specificity, 90.65% [95% CI, 84.54%-94.93%]) and mtmDR with the combination of RAS and DRAS (sensitivity, 90.23% [95% CI, 83.87%-94.69%]; specificity, 85.06% [95% CI, 78.88%-90.00%]). The area under the receiver operating characteristic curve was 0.95 for any DR and 0.89 for mtmDR.

CONCLUSIONS: This study showed a high accuracy for the detection of DR in different levels of severity with a single retinal photo per eye in an all-in-one solution, composed of a portable retinal camera powered by AI. Such a strategy holds great potential for increasing coverage rates of screening programs, contributing to prevention of avoidable blindness.

FINANCIAL DISCLOSURES: F.K.M. is a medical consultant for Phelcom Technologies. J.A.S. is Chief Executive Officer and proprietary of Phelcom Technologies. D.L. is Chief Technology Officer and proprietary of Phelcom Technologies. P.V.P. is an employee at Phelcom Technologies.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app