The effect of high-flow oxygen via tracheostomy on respiratory pattern and diaphragmatic function in patients with prolonged mechanical ventilation: A randomized, physiological, crossover study.

J Intensive Med 2024 April
BACKGROUND: Compared to conventional oxygen devices, high-flow oxygen treatment (HFOT) through the nasal cannulae has demonstrated clinical benefits. Limited data exist on whether such effects are also present in HFOT through tracheostomy. Hence, we aimed to examine the short-term effects of HFOT through tracheostomy on diaphragmatic function and respiratory parameters in tracheostomized patients on prolonged mechanical ventilation.

METHODS: A randomized, crossover, physiological study was conducted in our ICU between December 2020 and April 2021, in patients with tracheostomy and prolonged mechanical ventilation. The patients underwent a 30-min spontaneous breathing trial (SBT) and received oxygen either via T-piece or by HFOT through tracheostomy, followed by a washout period of 15-min breathing through the T-piece and receipt of 30-min oxygen with the other modality in a randomized crossover manner. At the start and end of each session, blood gasses, breathing frequency (f), and tidal volume (VT ) via a Wright's spirometer were measured, along with diaphragm ultrasonography including diaphragm excursion and diaphragmatic thickening fraction, which expressed the inspiratory muscle effort.

RESULTS: Eleven patients were enrolled in whom 19 sessions were uneventfully completed; eight patients were studied twice on two different days with alternate sessions; and three patients were studied once. Patients were randomly assigned to start the SBT with a T-piece ( n =10 sessions) or with HFOT ( n =9 sessions). With HFOT, VT and minute ventilation (VE ) significantly increased during SBT (from [465±119] mL to [549±134] mL, P <0.001 and from [12.4±4.3] L/min to [13.1±4.2] L/min, P <0.05, respectively), but they did not change significantly during SBT with T-piece (from [495±132] mL to [461±123] mL and from [12.8±4.4] mL to [12.0±4.4] mL, respectively); f/VT decreased during HFOT (from [64±31] breaths/(min∙L) to [49±24] breaths/(min∙L), P <0.001), but it did not change significantly during SBT with T-piece (from [59±28] breaths/(min∙L) to [64±33] breaths/(min∙L)); partial pressure of arterial oxygen increased during HFOT (from [99±39] mmHg to [132±48] mmHg, P <0.001), but it decreased during SBT with T-piece (from [124±50] mmHg to [83±22] mmHg, P <0.01). In addition, with HFOT, diaphragmatic excursion increased (from [12.9±3.3] mm to [15.7±4.4] mm, P <0.001), but it did not change significantly during SBT with T-piece (from [13.4±3.3] mm to [13.6±3.3] mm). The diaphragmatic thickening fraction did not change during SBT either with T-piece or with HFOT.

CONCLUSION: In patients with prolonged mechanical ventilation, HFOT through tracheostomy compared with T-piece improves ventilation, pattern of breathing, and oxygenation without increasing the inspiratory muscle effort.

TRIAL REGISTRATION: Clinicaltrials.gov ldentifer: NCT04758910.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app