We have located links that may give you full text access.
Role of Carotid Ultrasonography Combined with Monocyte/HDL Ratio in Internal Carotid Artery Stenosis.
Current medical imaging. 2024 April 19
BACKGROUND: Carotid duplex ultrasonography (DUS) is the primary screening tool for carotid artery stenosis, but has low reliability. MHR, which is the ratio of monocytes to high-density lipoprotein cholesterol (HDL-C), can be a marker for the degree and distribution of extracranial and intracranial atherosclerotic stenosis.
OBJECTIVE: We determined the diagnostic value of DUS+MHR for internal carotid artery (ICA) stenosis.
METHODS: We divided 273 hospitalized patients into non-stenosis (<50%) and ICA stenosis (≥50%) groups based on Digital Subtraction Angiography (DSA). We determined the peak systolic velocity (PSV) in the ICA on DUS, calculated the MHR, and investigated their relationship with ICA stenosis.
RESULTS: On DSA, 34.1% (93/273) patients had moderate-to-severe ICA stenosis. DUS and DSA showed low concordance for detecting ICA stenosis (kappa = 0.390). With increasing age, the incidence of moderate-to-severe ICA stenosis increased. PSV, monocyte count, and MHR were significantly greater in the stenosis group than in the non-stenosis group (P < 0.001), while the HDL-C level was significantly lower (P = 0.001). PSV (OR: 1.020, 95% CI: 1.011-1.029, P < 0.001) and MHR (OR: 5.662, 95% CI: 1.945-16.482, P = 0.002) were independent risk factors for ICA stenosis. The area under the receiver operating characteristic curve of PSV+MHR (0.819) was significantly higher than that of PSV or MHR alone (77.42% sensitivity, P = 0.0207; 73.89% specificity, P = 0.0032).
CONCLUSION: The combination of ICA PSV on DUS and MHR is better than PSV alone at identifying ICA stenosis and is well-suited to screen high-risk patients.
OBJECTIVE: We determined the diagnostic value of DUS+MHR for internal carotid artery (ICA) stenosis.
METHODS: We divided 273 hospitalized patients into non-stenosis (<50%) and ICA stenosis (≥50%) groups based on Digital Subtraction Angiography (DSA). We determined the peak systolic velocity (PSV) in the ICA on DUS, calculated the MHR, and investigated their relationship with ICA stenosis.
RESULTS: On DSA, 34.1% (93/273) patients had moderate-to-severe ICA stenosis. DUS and DSA showed low concordance for detecting ICA stenosis (kappa = 0.390). With increasing age, the incidence of moderate-to-severe ICA stenosis increased. PSV, monocyte count, and MHR were significantly greater in the stenosis group than in the non-stenosis group (P < 0.001), while the HDL-C level was significantly lower (P = 0.001). PSV (OR: 1.020, 95% CI: 1.011-1.029, P < 0.001) and MHR (OR: 5.662, 95% CI: 1.945-16.482, P = 0.002) were independent risk factors for ICA stenosis. The area under the receiver operating characteristic curve of PSV+MHR (0.819) was significantly higher than that of PSV or MHR alone (77.42% sensitivity, P = 0.0207; 73.89% specificity, P = 0.0032).
CONCLUSION: The combination of ICA PSV on DUS and MHR is better than PSV alone at identifying ICA stenosis and is well-suited to screen high-risk patients.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app