AIMS: Many portable electrocardiogram (ECG) devices have been developed to monitor patients at home, but the majority of these devices are single lead and only intended for rhythm disorders. We developed the miniECG, a smartphone-sized portable device with four dry electrodes capable of recording a high-quality multi-lead ECG by placing the device on the chest. The aim of our study was to investigate the ability of the miniECG to detect occlusive myocardial infarction (OMI) in patients with chest pain.
METHODS AND RESULTS: Patients presenting with acute chest pain at the emergency department of the University Medical Center Utrecht or Meander Medical Center, between May 2021 and February 2022, were included in the study. The clinical 12-lead ECG and the miniECG before coronary intervention were recorded. The recordings were evaluated by cardiologists and compared the outcome of the coronary angiography, if performed. A total of 369 patients were measured with the miniECG, 46 of whom had OMI. The miniECG detected OMI with a sensitivity and specificity of 65 and 92%, compared with 83 and 90% for the 12-lead ECG. Sensitivity of the miniECG was similar for different culprit vessels.
CONCLUSION: The miniECG can record a multi-lead ECG and rule-in ST-segment deviation in patients with occluded or near-occluded coronary arteries from different culprit vessels without many false alarms. Further research is required to add automated analysis to the recordings and to show feasibility to use the miniECG by patients at home.
METHODS AND RESULTS: Patients presenting with acute chest pain at the emergency department of the University Medical Center Utrecht or Meander Medical Center, between May 2021 and February 2022, were included in the study. The clinical 12-lead ECG and the miniECG before coronary intervention were recorded. The recordings were evaluated by cardiologists and compared the outcome of the coronary angiography, if performed. A total of 369 patients were measured with the miniECG, 46 of whom had OMI. The miniECG detected OMI with a sensitivity and specificity of 65 and 92%, compared with 83 and 90% for the 12-lead ECG. Sensitivity of the miniECG was similar for different culprit vessels.
CONCLUSION: The miniECG can record a multi-lead ECG and rule-in ST-segment deviation in patients with occluded or near-occluded coronary arteries from different culprit vessels without many false alarms. Further research is required to add automated analysis to the recordings and to show feasibility to use the miniECG by patients at home.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app