Add like
Add dislike
Add to saved papers

Evaluation of masticatory efficiency and OHRQoL in implant-retained overdenture with different numbers of implant in the edentulous mandible: a one-year follow-up prospective study.

PURPOSE: The aim of this article is to evaluate to the masticatory function performance and Oral Health-related Quality of Life (OHRQoL) in implant-retained overdenture compared with different implant number placements in the edentulous mandible.

METHODS: From 2013 to 2015, each patients received 3 implants (iSy-Implant, Camlog, Wimsheim, Germany) in intraforaminal mandible (34, 41/31, 44). After operation, inserted implants were gradually loaded and incorporated into an overdenture with a self-aligning attachment system (Locator abutments) in 3 + 3 + 3 months. Five checked points were performed chewing cycle test with multicolored chewing gum and OHIP-G14 questionnaire and a sum score questionnaire as following: pre-operation, one implant load (41/31), two implants loaded (33,43), three implants loaded and 1-year follow up.

RESULT: A total of 10 patients with 30 implants were placed, the survival rate of the implants was 100% within 1-year follow-up. Regarding the masticatory function analysis, for the higher number of chewing cycles, the higher mixing rate was observed. After 1 year, the inter-mixing rate without significant changes was found compared to the time after three implants were loaded with attachment system. The mean value of OHIP-G14 was 30.4 preoperatively, 21.1 after loading the first locator, 10.7 after loading two locator abutments, and 3.2 after loading all three locator abutments. After 1 year, OHIP-G14 was 2.6 without significantly changed. The mean of the sum score was 15.5 preoperatively, 27.8 after activation of the first locator, 39.4 after activation of two locators, 46.2 after activation of all three locators, and 47.3 after 1 year. An increase of 0.7 sum score units per time point was observed. No significance was detectable, analogous to OHIP-G14, compared to the time of activation of all three locator setups (p-value = 0.22).

CONCLUSIONS: A significant improvement in masticatory function performance and OHRQoL was evaluated with the increasing number of implants with locator attachment in edentulous mandible. With the investigation of the OHIP-G14 and sum score, the results of patient report outcome might be associated with the increase in the number of implants.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app