[Application of analgesia and sedation under BIS monitoring combined with hydraulic coupling intracranial pressure monitoring in severe craniocerebral injury].

OBJECTIVE: To investigate the clinical value of analgesia and sedation under bispectral index (BIS) monitoring combined with hydraulic coupled intracranial pressure (ICP) monitoring in severe craniocerebral injury (sTBI).

METHODS: (1) A prospective self-controlled parallel control study was conducted. A total of 32 patients with sTBI after craniotomy admitted to the intensive care unit (ICU) of the First People's Hospital of Huzhou from December 2020 to July 2021 were selected as the research objects. ICP was monitored by Codman monitoring system and hydraulically coupled monitoring system, and the difference and correlation between them were compared. (2) A prospective randomized controlled study was conducted. A total of 108 sTBI patients admitted to the ICU of the First People's Hospital of Huzhou from August 2021 to August 2022 were selected patients were divided into 3 groups according to the random number table method. All patients were given routine treatment after brain surgery. On this basis, the ICP values of the patients in group A (35 cases) were monitored by Codman monitoring system, the ICP values of the patients in group B (40 cases) were monitored by hydraulic coupling monitoring system, and the ICP values of the patients in group C (33 cases) were monitored combined with hydraulic coupling monitoring system, and the analgesia and sedation were guided by BIS. The ICP after treatment, cerebrospinal fluid drainage time, ICP monitoring time, ICU stay time, complications and Glasgow outcome score (GOS) at 6 months after surgery were compared among the 3 groups. In addition, patients in group B and group C were further grouped according to the waveforms. If P1 = P2 wave or P2 and P3 wave were low, they were classified as compensatory group. If the round wave or P2 > P1 wave was defined as decompensated group, the GOS scores of the two groups at 6 months after operation were compared.

RESULTS: (1) There was no significant difference in ICP values measured by Codman monitoring system and hydraulic coupling monitoring system in the same patient (mmHg: 11.94±1.76 vs. 11.88±1.90, t = 0.150, P = 0.882; 1 mmHg≈0.133 kPa). Blan-altman analysis showed that the 95% consistency limit (95%LoA) of ICP values measured by the two methods was -4.55 to 4.68 mmHg, and all points fell within 95%LoA, indicating that the two methods had a good correlation. (2) There were no significant differences in cerebrospinal fluid drainage time, ICP monitoring time, ICU stay time, and incidence of complications such as intracranial infection, intracranial rebleeding, traumatic hydrocephalus, cerebrospinal fluid leakage, and accidental extubation among the 3 groups of sTBI patients (P > 0.05 or P > 0.017). The ICP value of group C after treatment was significantly lower than that of group A and group B (mmHg: 20.94±2.37 vs. 25.86±3.15, 26.40±3.09, all P < 0.05), the incidence of pulmonary infection (9.1% vs. 45.7%, 42.5%), seizure (3.0% vs. 31.4%, 30.0%), reoperation (3.0% vs. 31.4%, 40.0%), and poor prognosis 6 months after operation (33.3% vs. 65.7%, 65.0%) were significantly lower than those in group A and group B (all P < 0.017). According to the hydraulic coupling waveform, GOS scores of 35 patients in the compensated group were significantly higher than those of 38 patients in the decompensated group 6 months after operation (4.03±1.18 vs. 2.39±1.50, t = 5.153, P < 0.001).

CONCLUSIONS: The hydraulic coupled intracranial pressure monitoring system has good accuracy and consistency in measuring ICP value, and it can better display ICP waveform changes than the traditional ICP monitoring method, and has better prediction value for prognosis evaluation, which can replace Codman monitoring to accurately guide clinical work. In addition, analgesia and sedation under BIS monitoring combined with hydraulic coupled ICP monitoring can effectively reduce ICP, reduce the incidence of complications, and improve the prognosis, which has high clinical application value.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app