Add like
Add dislike
Add to saved papers

Feasibility and tolerability of breath-hold in liver stereotactic body radiotherapy with surface guided radiotherapy.

PURPOSE: Intrafractional motion constitutes a significant challenge in SBRT (Stereotactic Body Radiotherapy).The breath-hold (BH) technique is employed to mitigate tumor motion; however, ensuring reproducibility and consistency remains critically important. Surface tracking systems, integrated into the treatment process, facilitate motion tracking through three-dimensional camera technology. Surface guidance has been incorporated with Varian EDGE (Varian Medical Systems, Palo Alto, CA, USA) and has been utilized at multiple treatment sites within our department since 2018. Drawing on four years of experience, this study aims to publish patient experience, assess the feasibility, and evaluate the tolerability of breath-hold during SBRT with surface guided radiotherapy (SGRT), particularly focusing on a specific subgroup: patients with liver metastases.

METHODS: Prospective evaluation was conducted on patients with liver metastases undergoing breath-hold SBRT with SGRT. A two-step survey consisting of seven questions was administered after CT simulation and treatment. Treatment duration and the number of breath-holds were recorded. Additionally, factors potentially influencing SGRT and treatment time were assessed.

RESULTS: Between April 2021 and May 2022, a total of 41 patients underwent 171 fractions of treatment. According to the questionnaire, prior training was found to be beneficial, and breath-holding during the procedure was tolerable. Patients reported experiencing slight stress due to their active participation in the treatment. Factors such as Karnofsky Performance Status (KPS), age, lung volume, conditions affecting lung capacity, previous breath-hold history, and being a native speaker showed no correlation with treatment time. Moreover, these factors did not correlate with the tolerability of breath-hold during SGRT. However, female patients showed better breath-holding performance in SGRT treatments compared to male patients (p: 0.02).

CONCLUSIONS: The application of breath-hold with SGRT procedures is tolerable and feasible in liver SBRT treatments. There exists no specific subgroup that cannot tolerate this method.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app