Add like
Add dislike
Add to saved papers

Doppler Echocardiographic Phenotypes in Suspected 'Severe' Aortic Stenosis Matrix-based Approach to Diagnosis and Management.

BACKGROUND: Among patients with suspected severe aortic stenosis [AS], Doppler echocardiographic [DE] data are often discordant and further analysis is required for accurate diagnosis and optimal management. In this study an automated matrix-based approach was applied to an echocardiographic database of patients with AS that identified 5 discrete echocardiographic data patterns, 1 concordant and 4 discordant, each reflecting a particular pathophysiology/measurement error that guides further work-up and management.

METHODS: A primary/discovery cohort of consecutive echocardiographic studies with at least one DE parameter of severe AS and analogous data from an independent secondary/validation cohort were retrospectively analyzed. Parameter thresholds for inclusion were aortic valve area [AVA] <1.0 cm2 , transaortic mean gradient [MG] >40 mmHg, and/or transaortic peak velocity >4.0 m/s. Doppler velocity index [DVI] was also determined. Logic provided by an in-line SQL query embedded within the database was used to assign each patient to one of five discrete matrix patterns, each reflecting one or more specific pathophysiologies. Feasibility of automated pattern-driven triage of discordant cases was also evaluated.

RESULTS: In both cohorts, data from each patient fitted only one data pattern. Of the 4643 primary cohort patients, 39% had concordant parameters for severe AS and DVI <0.30 (pattern 1). 35% had AVA <1.0 cm2 , MG <40 mmHg, DVI <0.30 (pattern 2). 9% had MG >40 mmHg with DVI >0.30 (pattern 3). 10% had AVA <1.0 cm2 , MG <40 mmHg, DVI >0.30, due to small left ventricular outflow tract (LVOT) measurements (pattern 4). 7% had MG >40 mmHg, AVA >1.0 cm2 , DVI <0.30, due to large LVOT measurements (pattern 5). Findings were validated among the 387 secondary cohort patients in whom pattern distribution was remarkably similar.

CONCLUSIONS: Matrix-based pattern recognition permits automated in-line identification of specific pathophysiology and/or measurement error among patients with suspected severe AS and discordant DE data.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app