We have located links that may give you full text access.
Partial arch replacement of type A aortic dissection after thoracic endovascular aortic repair for type B dissection.
Egyptian Heart Journal : EHJ 2023 October 7
BACKGROUND: Stent graft-induced new entry (SINE), defined as the stent graft-induced formation of a new entry point for blood to enter an area, is increasingly being observed after thoracic endovascular aortic repair (TEVAR) for Stanford type B aortic dissection worldwide. We herein describe a case of Stanford type A aortic dissection due to proximal SINE after TEVAR for Stanford type B dissection.
CASE PRESENTATION: This case involved a 58-year-old man with type A aortic dissection due to SINE. Six years previously, he had developed severe back pain and was diagnosed with type B aortic dissection after computed tomography examination. Because the primary entry was positioned at the descending aorta, we conducted TEVAR for exclusion of the entry with a GORE TAG conformable thoracic aortic graft. He was thereafter followed by our hospital. Six years later, he developed jaw pain and was examined at another hospital. He was transferred to our hospital because of the possibility of type A dissection. Computed tomography revealed type A aortic dissection with proximal site SINE. Emergency partial arch replacement was conducted, and he was discharged on postoperative day 27. Because the entry was at the lesser curve of the arch, we excluded the entry and conducted partial arch replacement.
CONCLUSIONS: In this case, proximal SINE occurred 6 years after TEVAR. Because SINE may occur even in the long term after TEVAR, careful follow-up is necessary.
CASE PRESENTATION: This case involved a 58-year-old man with type A aortic dissection due to SINE. Six years previously, he had developed severe back pain and was diagnosed with type B aortic dissection after computed tomography examination. Because the primary entry was positioned at the descending aorta, we conducted TEVAR for exclusion of the entry with a GORE TAG conformable thoracic aortic graft. He was thereafter followed by our hospital. Six years later, he developed jaw pain and was examined at another hospital. He was transferred to our hospital because of the possibility of type A dissection. Computed tomography revealed type A aortic dissection with proximal site SINE. Emergency partial arch replacement was conducted, and he was discharged on postoperative day 27. Because the entry was at the lesser curve of the arch, we excluded the entry and conducted partial arch replacement.
CONCLUSIONS: In this case, proximal SINE occurred 6 years after TEVAR. Because SINE may occur even in the long term after TEVAR, careful follow-up is necessary.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app