In-hospital cardiac arrest rhythm analysis by anesthesiologists: a diagnostic performance study.

PURPOSE: In-hospital cardiac arrest is associated with high morbidity and mortality, with an overall survival rate at one year of approximately 13%. The first cardiac rhythm is often analyzed by anesthesiologist-intensivists. We aimed to determine the diagnostic performance of anesthesiologist-intensivists when distinguishing between shockable and nonshockable rhythms.

METHODS: We conducted a simulation-based, multicentre, prospective, observational study between May 2019 and March 2020. The responses of the participants were used to calculate individual sensitivity (defined as the proportion of decisions to shock for shockable rhythms) and individual specificity (defined as the proportion of decisions not to shock for nonshockable rhythms). The main outcome measure was the overall diagnostic performance, defined as the overall sensitivity and specificity. Secondary outcome measures were the sensitivity and specificity of participants' decisions for each type of cardiac arrest rhythm and their decision-making times.

RESULTS: Among the 267 physicians contacted, 179 (67%) completed the test. The median [interquartile range (IQR)] overall sensitivity was 88 [79-95]% and the median overall specificity was 86 [77-92]%. Among shockable rhythms, the median [IQR] sensitivity was 100 [100-100]% for ventricular tachycardia (VT), 100 [100-100]% for coarse ventricular fibrillation (VF), and 60 [20-100]% for fine VF. The median [IQR] specificities for nonshockable rhythms were 93 [86-100]% for asystole and 83 [72-86]% for pulseless electrical activity. The median decision times ranged from 2.0 to 3.5 sec.

CONCLUSION: Anesthesiologist-intensivists were quickly and effectively able to analyze rhythms in this simulation-based study. Participants' sensitivity in deciding to deliver shocks for VT and coarse VF was excellent, while specificity of their decisions for pulseless electrical activity was insufficient.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app