Dispersion of repolarization increases with cardiac resynchronization therapy and is associated with left ventricular reverse remodeling.
Journal of Electrocardiology 2022 April 19
PURPOSE: Cardiac resynchronization therapy (CRT) reduces ventricular activation times and electrical dyssynchrony, however the effect on repolarization is unclear. In this study, we sought to investigate the effect of CRT and left ventricular (LV) remodeling on dispersion of repolarization using electrocardiographic imaging (ECGi).
METHODS: 11 patients with heart failure and electrical dyssynchrony underwent ECGi 1-day and 6-months post CRT. Reconstructed epicardial electrograms were used to create maps of activation time, repolarization time (RT) and activation recovery intervals (ARI) and calculate measures of RT, ARI and their dispersion. ARI was corrected for heart rate (cARI).
RESULTS: Compared to baseline rhythm, LV cARI dispersion was significantly higher at 6 months (28.2 ± 7.7 vs 36.4 ± 7.2 ms; P = 0.03) but not after 1 day (28.2 ± 7.7 vs 34.4 ± 6.8 ms; P = 0.12). There were no significant differences from baseline to CRT for mean LV cARI or RT metrics. Significant LV remodeling (>15% reduction in end-systolic volume) was an independent predictor of increase in LV cARI dispersion (P = 0.04) and there was a moderate correlation between the degree of LV remodeling and the relative increase in LV cARI dispersion (R = -0.49) though this was not statistically significant (P = 0.12).
CONCLUSION: CRT increases LV cARI dispersion, but this change was not fully apparent until 6 months post implant. The effects of CRT on LV cARI dispersion appeared to be dependent on LV reverse remodeling, which is in keeping with evidence that the risk of ventricular arrhythmia after CRT is higher in non-responders compared to responders.
METHODS: 11 patients with heart failure and electrical dyssynchrony underwent ECGi 1-day and 6-months post CRT. Reconstructed epicardial electrograms were used to create maps of activation time, repolarization time (RT) and activation recovery intervals (ARI) and calculate measures of RT, ARI and their dispersion. ARI was corrected for heart rate (cARI).
RESULTS: Compared to baseline rhythm, LV cARI dispersion was significantly higher at 6 months (28.2 ± 7.7 vs 36.4 ± 7.2 ms; P = 0.03) but not after 1 day (28.2 ± 7.7 vs 34.4 ± 6.8 ms; P = 0.12). There were no significant differences from baseline to CRT for mean LV cARI or RT metrics. Significant LV remodeling (>15% reduction in end-systolic volume) was an independent predictor of increase in LV cARI dispersion (P = 0.04) and there was a moderate correlation between the degree of LV remodeling and the relative increase in LV cARI dispersion (R = -0.49) though this was not statistically significant (P = 0.12).
CONCLUSION: CRT increases LV cARI dispersion, but this change was not fully apparent until 6 months post implant. The effects of CRT on LV cARI dispersion appeared to be dependent on LV reverse remodeling, which is in keeping with evidence that the risk of ventricular arrhythmia after CRT is higher in non-responders compared to responders.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app