CDISC-compliant clinical trial imaging management system with automatic verification and data Transformation: Focusing on tumor response assessment data in clinical trials.

OBJECTIVE: Major issues in imaging data management of tumor response assessment in clinical trials include high human errors in data input and unstandardized data structures, warranting a new breakthrough IT solution. Thus, we aim to develop a Clinical Data Interchange Standards Consortium (CDISC)-compliant clinical trial imaging management system (CTIMS) with automatic verification and transformation modules for implementing the CDISC Study Data Tabulation Model (SDTM) in the tumor response assessment dataset of clinical trials.

MATERIALS AND METHODS: In accordance with various CDISC standards guides and Response Evaluation Criteria in Solid Tumors (RECIST) guidelines, the overall system architecture of CDISC-compliant CTIMS was designed. Modules for standard-compliant electronic case report form (eCRF) to verify data conformance and transform into SDTM data format were developed by experts in diverse fields such as medical informatics, medical, and clinical trial. External validation of the CDISC-compliant CTIMS was performed by comparing it with our previous CTIMS based on real-world data and CDISC validation rules by Pinnacle 21 Community Software.

RESULTS: The architecture of CDISC-compliant CTIMS included the standard-compliant eCRF module of RECIST, the automatic verification module of the input data, and the SDTM transformation module from the eCRF input data to the SDTM datasets based on CDISC Define-XML. This new system was incorporated into our previous CTIMS. External validation demonstrated that all 176 human input errors occurred in the previous CTIMS filtered by a new system yielding zero error and CDISC-compliant dataset. The verified eCRF input data were automatically transformed into the SDTM dataset, which satisfied the CDISC validation rules by Pinnacle 21 Community Software.

CONCLUSIONS: To assure data consistency and high quality of the tumor response assessment data, our new CTIMS can minimize human input error by using standard-compliant eCRF with an automatic verification module and automatically transform the datasets into CDISC SDTM format.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app