Direct and Indirect Flap Measurements in Femtosecond Laser-Assisted In Situ Keratomileusis.

Cornea 2018 December 29
PURPOSE: To compare direct and indirect LASIK flap thickness measurements using ultrasound and Scheimpflug technology.

METHODS: Eighty-two eyes treated with laser-assisted in situ keratomileusis refractive surgery using a femtosecond laser (IntraLase FS150) were prospectively included in the study. Flap thickness was set to 115 μm. Corneal flap thickness was measured using the direct method-ie, ultrasound pachymetry immediately after flap construction in the presence of cavitation bubbles-and indirect methods, with subtraction of intraoperative post-lift corneal thickness measured using ultrasound pachymetry (intrastroma) from preoperative central corneal thickness using ultrasound (Indirect-US) or Scheimpflug thinnest pachymetry (Indirect-Scheimpflug).

RESULTS: Mean flap thickness was overestimated using the indirect methods, Indirect-US and Indirect-Scheimpflug (122.6 ± 24.5 μm and 128.1 ± 26.1 μm, respectively; P < 0.0060 and P < 0.0001, respectively). There were no significant correlations between the direct and indirect methods. Indirect-Scheimpflug was significantly higher (P = 0.0122) than Indirect-US. The closest average flap thickness compared with the set parameter of 115 μm was that of the direct method (115.6 ± 8.6 μm; 95% confidence interval: -1.3 to 2.5; P = 0.5163). The direct method provided the lowest SD of all groups (SD: 8.64).

CONCLUSIONS: The direct method of flap thickness measurement was the most comparable to the set parameter compared with the indirect subtraction methods. Additional studies are needed to determine which method allows for the most accurate measurement of flap thickness.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app