Cerebral Artery Vasospasm Detection Using Transcranial Doppler Signal Analysis.
Journal of Ultrasound in Medicine : Official Journal of the American Institute of Ultrasound in Medicine 2019 August
OBJECTIVES: Silent cerebral artery vasospasm in aneurysmal subarachnoid hemorrhage causes serious complications such as cerebral ischemia and death. A transcranial Doppler (TCD) ultrasound system is a noninvasive device that can effectively detect cerebral artery vasospasm as soon as it sets in, even before and in the absence of clinical deterioration. Continuous or even daily TCD monitoring is challenging because of the operator expertise and certification required in the form of a trained sonographer and interpretive experience required in the form of an additionally trained and certified physician to perform these studies. This barrier exists because of a lack of automation for detection (without human intervention) of cerebral artery vasospasm using TCD ultrasound. To overcome this barrier, we present an algorithm that automates detection of cerebral artery vasospasm.
METHODS: We extracted features such as the energy, energy entropy, zero-crossing rate, spectral centroid, spectral speed, spectral entropy, spectral flux, spectral roll-off, harmonic ratio, chroma, and Mel frequency cepstral coefficients for signal classification. Then we applied principal component analysis to reduce the data dimensionality.
RESULTS: All of the chosen features were used for training a decision-tree classifier. The algorithm had high accuracy for cerebral artery vasospasm detection, with overall sensitivity of 87.5% and specificity of 89.74%.
CONCLUSIONS: The algorithm has the potential for development into a continuous cerebral artery vasospasm monitor.
METHODS: We extracted features such as the energy, energy entropy, zero-crossing rate, spectral centroid, spectral speed, spectral entropy, spectral flux, spectral roll-off, harmonic ratio, chroma, and Mel frequency cepstral coefficients for signal classification. Then we applied principal component analysis to reduce the data dimensionality.
RESULTS: All of the chosen features were used for training a decision-tree classifier. The algorithm had high accuracy for cerebral artery vasospasm detection, with overall sensitivity of 87.5% and specificity of 89.74%.
CONCLUSIONS: The algorithm has the potential for development into a continuous cerebral artery vasospasm monitor.
Full text links
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app