We have located links that may give you full text access.
Development of bioanalytical HPLC method for simultaneous determination of the antialzhiemer, donepezil hydrochloride and the antidepressant, citalopram hydrobromide in raw materials, spiked human plasma and tablets dosage form.
Annales Pharmaceutiques Françaises 2018 October 25
OBJECTIVES: A novel, fast and sensitive HPLC method has been developed for the simultaneous bioanalytical determination of Donepezil hydrochloride (DON) and Citalopram hydrobromide (CTP) in raw materials, spiked human plasma and tablets.
MATERIALS AND METHODS: Elution of both drugs was achieved with very good resolution using a RP-C18 chromatographic column, samples were analyzed using Hypersil Gold (100mm×4.6mm), 5μm particle size column and an isocratic binary mobile phase consists of phosphate buffer (0.05 M): acetonitrile (65:35). A Diode array detector at wavelength 232nm was used. Chromatographic separation was within a short run time (less than 7minutes) for both drugs.
RESULTS: Retention times for DON and CTP were 4.5 and 5.8min, respectively. Linear calibration curves were obtained for DON and CTP over the concentration ranges of 0.1-10 and 0.1-50μg/mL. The mean extraction recoveries from spiked plasma were 93.22 and 92.64 for DON and CTP, respectively. The limits of detection and quantification were 0.017, 0.035μg/mL and 0.052, 0.106μg/mL for DON and CTP, respectively.
CONCLUSION: The proposed method was successfully applied to the analysis of the cited drugs in raw materials, spiked human plasma and tablets with excellent accuracy and precision.
MATERIALS AND METHODS: Elution of both drugs was achieved with very good resolution using a RP-C18 chromatographic column, samples were analyzed using Hypersil Gold (100mm×4.6mm), 5μm particle size column and an isocratic binary mobile phase consists of phosphate buffer (0.05 M): acetonitrile (65:35). A Diode array detector at wavelength 232nm was used. Chromatographic separation was within a short run time (less than 7minutes) for both drugs.
RESULTS: Retention times for DON and CTP were 4.5 and 5.8min, respectively. Linear calibration curves were obtained for DON and CTP over the concentration ranges of 0.1-10 and 0.1-50μg/mL. The mean extraction recoveries from spiked plasma were 93.22 and 92.64 for DON and CTP, respectively. The limits of detection and quantification were 0.017, 0.035μg/mL and 0.052, 0.106μg/mL for DON and CTP, respectively.
CONCLUSION: The proposed method was successfully applied to the analysis of the cited drugs in raw materials, spiked human plasma and tablets with excellent accuracy and precision.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university