Add like
Add dislike
Add to saved papers

Single-Nanoparticle Tracking with Angstrom Localization Precision and Microsecond Time Resolution.

Biophysical Journal 2018 November 18
Gold nanoparticles (AuNPs) have been used as a contrast agent for optical imaging of various single biomolecules. Because AuNPs have high scattering efficiency without photobleaching, biomolecular dynamics have been observed with nanometer localization precision and sub-millisecond time resolution. To understand the working principle of biomolecular motors in greater detail, further improvement of the localization precision and time resolution is necessary. Here, we investigated the lower limit of localization precision achievable with AuNPs and the fundamental law, which determines the localization precision. We first used objective-lens-type total internal reflection dark-field microscopy to obtain a scattering signal from an isolated AuNP. The localization precision was inversely proportional to the square root of the photon number, which is consistent with theoretical estimation. The lower limit of precision for a 40 nm AuNP was ∼0.3 nm with 1 ms time resolution and was restricted by detector saturation. To achieve higher localization precision, we designed and constructed an annular illumination total internal reflection dark-field microscopy system with an axicon lens, which can illuminate the AuNPs at high laser intensity without damaging the objective lens. In addition, we used high image magnification to avoid detector saturation. Consequently, we achieved 1.3 Å localization precision for 40 nm AuNPs and 1.9 Å localization precision for 30 nm AuNPs at 1 ms time resolution. Furthermore, even at 33 μs time resolution, localization precisions at 5.4 Å for 40 nm AuNPs and at 1.7 nm for 30 nm AuNPs were achieved. We then observed motion of head of kinesin-1 labeled with AuNP at microsecond time resolution. Transition cycles of bound/unbound states and tethered diffusion of unbound head during stepping motion on microtubule were clearly captured with higher time resolution or smaller AuNP than those used in previous studies, indicating applicability to single-molecule imaging of biomolecular motors.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app