Add like
Add dislike
Add to saved papers

Long-term results after the Ross procedure with the decellularized AutoTissue Matrix P® bioprosthesis used for pulmonary valve replacement.

OBJECTIVES: Since 1967, the Ross procedure has been performed to treat aortic valve disease using homografts for pulmonary valve replacement. The decellularized Matrix P® prosthesis was developed to overcome (some) limitations of homografts. Until now, the long-term outcome data have been unavailable.

METHODS: Between 2002 and 2010, the Ross procedures using the Matrix P prosthesis were performed in 492 adult patients (mean age 57.2 ± 10.6 years, range 21-73 years) at our institution. Patient data were prospectively collected and analysed (3617.3 patient-years, mean follow-up 7.7  ±  4.3 years). Completeness of follow-up at 1, 5 and 10 years was 98.4%, 94.5% and 91.0%, respectively.

RESULTS: Hospital mortality was 3.9% (n  = 19). During follow-up, 121 patients died resulting in a survival rate at 5, 10 and 12.5 years of 82.8  ±  1.7%, 70.4  ±  2.3% and 62.4  ±  2.9%, respectively. Echocardiography revealed a high incidence of relevant dysfunction of the Matrix P prosthesis and subsequent right ventricular failure. Primary reoperation/reintervention was necessary for 150 Matrix P and 48 autografts. Freedom from pulmonary valve reoperation at 5, 10 and 12.5 years was 76.2  ±  2.1%, 58.6  ±  2.9% and 53.4  ±  3.4%, respectively. The autograft function and the left ventricular function showed similar results as previously reported with a freedom from autograft reoperation at 5, 10 and 12.5 years of 91.8  ±  1.4%, 86.1  ±  2.0% and 86.1  ±  2.0%, respectively.

CONCLUSIONS: The Matrix P prosthesis used for the right ventricular outflow tract reconstruction in the Ross procedure showed unfavourable long-term echocardiographic results with a high rate of reoperation/reintervention for structural pulmonary valve failure. As a consequence, long-term survival of this patient cohort was impaired. Based on these findings, the use of the Matrix P prosthesis for pulmonary valve replacement for Ross procedures in adults should not be recommended.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app