We have located links that may give you full text access.
Comparison of cone-beam computed tomography with bitewing radiography for detection of periodontal bone loss and assessment of effects of different voxel resolutions: an in vitro study.
Oral Radiology 2018 June 9
OBJECTIVE: The aim of the study was to compare intraoral radiographs and CBCT images for detection of horizontal periodontal bone loss, and to investigate the diagnostic effect of different voxel resolutions in CBCT imaging.
METHODS: A total of 240 sites with horizontal bone loss were measured on the buccal, lingual, mesial, and distal surfaces of 60 posterior teeth in four maxillary and six mandibular bones obtained from cadavers (dry skulls). Direct measurements on the dry skulls were accepted as the gold standard values. Measurements on CBCT images at two different voxel resolutions (0.250 and 0.160 mm3 ) and intraoral bitewing radiographs were compared with one another and with the gold standard values.
RESULTS: The measurements on the CBCT images at two voxel resolutions and bitewing radiographs did not differ significantly (p > 0.05) from the direct measurements on the dry skulls. No significant difference was found between the bitewing radiographs and CBCT images for measurements in the mesial and distal regions (p > 0.05). There was no significant difference between the measurements on the buccal and lingual surfaces at the two different voxel resolutions (p > 0.05).
CONCLUSIONS: CBCT scans are recommended for evaluation of buccal and lingual bone loss to avoid intraoral radiographs that exceed routine examination of interproximal alveolar bone loss. Furthermore, instead of basing the voxel size on the required CBCT scans, it is recommended to select the smallest possible field of view to reduce the dose of radiation.
METHODS: A total of 240 sites with horizontal bone loss were measured on the buccal, lingual, mesial, and distal surfaces of 60 posterior teeth in four maxillary and six mandibular bones obtained from cadavers (dry skulls). Direct measurements on the dry skulls were accepted as the gold standard values. Measurements on CBCT images at two different voxel resolutions (0.250 and 0.160 mm3 ) and intraoral bitewing radiographs were compared with one another and with the gold standard values.
RESULTS: The measurements on the CBCT images at two voxel resolutions and bitewing radiographs did not differ significantly (p > 0.05) from the direct measurements on the dry skulls. No significant difference was found between the bitewing radiographs and CBCT images for measurements in the mesial and distal regions (p > 0.05). There was no significant difference between the measurements on the buccal and lingual surfaces at the two different voxel resolutions (p > 0.05).
CONCLUSIONS: CBCT scans are recommended for evaluation of buccal and lingual bone loss to avoid intraoral radiographs that exceed routine examination of interproximal alveolar bone loss. Furthermore, instead of basing the voxel size on the required CBCT scans, it is recommended to select the smallest possible field of view to reduce the dose of radiation.
Full text links
Trending Papers
A Personalized Approach to the Management of Congestion in Acute Heart Failure.Heart International 2023
Potential Mechanisms of the Protective Effects of the Cardiometabolic Drugs Type-2 Sodium-Glucose Transporter Inhibitors and Glucagon-like Peptide-1 Receptor Agonists in Heart Failure.International Journal of Molecular Sciences 2024 Februrary 21
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app