OBJECTIVES: The optimal level of suction on digital chest drainage devices after lobectomy using video-assisted thoracoscopic surgery (VATS) is unknown and varies between thoracic centres. In this randomized controlled trial, we assessed the potential benefits of low suction of -2 cmH2O compared to -10 cmH2O, using a digital drainage device.
METHODS: Two hundred and twenty-eight patients were randomized into 2 groups after VATS lobectomy for suspected or confirmed lung cancer. Primary outcome was time to chest drain removal. Drain data were obtained from the digital drainage devices, and patient data were obtained from medical records during admission, with a follow-up until postoperative day 30.
RESULTS: For the -2 cmH2O and -10 cmH2O groups, median (interquartile range) drainage duration was 27.4 h (23.3-71.2) and 47.5 h (24.5-117.8) (P = 0.047), and the incidence of prolonged air leak >5 days was 14.4% and 24.3% (P = 0.089), respectively. Median total fluid production was 566 h (329-1155) ml and 795 h (454-1605) ml (P = 0.007). Median time to consistent air leak cessation (<20 ml/min) was 5.2 h (0.3-34.2) and 23.7 h (0.8-90.8) (P < 0.001). There were no differences in the proportion or the size of the pneumothorax or subcutaneous emphysema after drain removal, and no differences were observed in postoperative morbidity. Median length of in-hospital stay was 2.0 days (2.0-5.8) and 3.0 days (2.0-9.0) (P = 0.18).
CONCLUSIONS: A low suction level significantly shortened drainage duration, time to air leak cessation and total fluid production, without increasing morbidity.
CLINICAL TRIAL REGISTRATION NUMBER: NCT02911259.
METHODS: Two hundred and twenty-eight patients were randomized into 2 groups after VATS lobectomy for suspected or confirmed lung cancer. Primary outcome was time to chest drain removal. Drain data were obtained from the digital drainage devices, and patient data were obtained from medical records during admission, with a follow-up until postoperative day 30.
RESULTS: For the -2 cmH2O and -10 cmH2O groups, median (interquartile range) drainage duration was 27.4 h (23.3-71.2) and 47.5 h (24.5-117.8) (P = 0.047), and the incidence of prolonged air leak >5 days was 14.4% and 24.3% (P = 0.089), respectively. Median total fluid production was 566 h (329-1155) ml and 795 h (454-1605) ml (P = 0.007). Median time to consistent air leak cessation (<20 ml/min) was 5.2 h (0.3-34.2) and 23.7 h (0.8-90.8) (P < 0.001). There were no differences in the proportion or the size of the pneumothorax or subcutaneous emphysema after drain removal, and no differences were observed in postoperative morbidity. Median length of in-hospital stay was 2.0 days (2.0-5.8) and 3.0 days (2.0-9.0) (P = 0.18).
CONCLUSIONS: A low suction level significantly shortened drainage duration, time to air leak cessation and total fluid production, without increasing morbidity.
CLINICAL TRIAL REGISTRATION NUMBER: NCT02911259.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app