INTRODUCTION: sedation substantially improves the quality of digestive endoscopy procedures but may result in severe complications.
METHODS: a joint commission-based multidisciplinary protocol was used to define a protocol for sedation by non-anesthesiologists. ASA 4 patients were excluded, as well as patients with a difficult airway, complex procedures and deep sedation. Quality based on the analysis of 9 indicators were monitored. Incomplete procedures were also monitored in order to assess efficacy.
RESULTS: patient safety was established based on a very low incidence of complications and a rate of respiratory events of 1.07. Furthermore, a low rate of hypotension and bradycardia was found, as well as a low rate of pain, either during or after endoscopy and an incidence of unexpected admissions lower than 0.5%. The quality indicators measured reflect the evolution of the results of the program.
CONCLUSIONS: ongoing sedation program monitoring in endoscopy allows the control of different quality dimensions and the implementation of steps for process improvement.
METHODS: a joint commission-based multidisciplinary protocol was used to define a protocol for sedation by non-anesthesiologists. ASA 4 patients were excluded, as well as patients with a difficult airway, complex procedures and deep sedation. Quality based on the analysis of 9 indicators were monitored. Incomplete procedures were also monitored in order to assess efficacy.
RESULTS: patient safety was established based on a very low incidence of complications and a rate of respiratory events of 1.07. Furthermore, a low rate of hypotension and bradycardia was found, as well as a low rate of pain, either during or after endoscopy and an incidence of unexpected admissions lower than 0.5%. The quality indicators measured reflect the evolution of the results of the program.
CONCLUSIONS: ongoing sedation program monitoring in endoscopy allows the control of different quality dimensions and the implementation of steps for process improvement.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app