We have located links that may give you full text access.
Body composition evaluation with computed tomography: Contrast media and slice thickness cause methodological errors.
Nutrition 2018 August 10
OBJECTIVE: Although computed tomography (CT) is frequently used to determine body composition, the effects of using different CT protocols is not well known. The aim of this study was to determine whether contrast media phase, radiation dose, and slice thickness in CT affect body composition segmentation.
METHODS: Clinically indicated perfusion CTs of the upper abdomen in 20 patients (seven women) between 40 and 87 y of age with high suspicion of hepatocellular carcinoma were analyzed retrospectively. Axial images from the L3 level with varying imaging delay were reconstructed after contrast media injection (18 images per patient), slice thickness (5 images, 2-10 mm), and radiation dose (4 images with one-third to four-thirds of standard dose). Muscle and fat areas were segmented semiautomatically by drawing regions of interests and using established cutoff thresholds. Skeletal muscle index (SMI), steatotic muscle area, and adipose tissue index, as well as muscle attenuation and fat attenuation, were evaluated.
RESULTS: Average SMI increased by up to 2.8% after contrast media injection. Steatotic muscle area decreased by ≤13.8%, and adipose tissue index decreased by ≤6.5%. Muscle attenuation increased after contrast media injection, whereas fat attenuation decreased (all P < 0.001). SMI decreased by 1.9% on average when increasing slice thickness from 2 to 10 mm. Steatotic muscle area increased by ≤3.3%, and adipose tissue index increased by ≤1.5% (all P < 0.05). Muscle attenuation did not change significantly with reconstruction thickness. Radiation dose had no effect on estimated area of spinal muscle, fatty spinal muscle, or visceral fat.
CONCLUSIONS: Contrast media have a strong effect on the evaluation of body composition, whereas the influence of slice thickness is less pronounced. Radiation dose can be reduced by ≥66% without significantly affecting segmentation.
METHODS: Clinically indicated perfusion CTs of the upper abdomen in 20 patients (seven women) between 40 and 87 y of age with high suspicion of hepatocellular carcinoma were analyzed retrospectively. Axial images from the L3 level with varying imaging delay were reconstructed after contrast media injection (18 images per patient), slice thickness (5 images, 2-10 mm), and radiation dose (4 images with one-third to four-thirds of standard dose). Muscle and fat areas were segmented semiautomatically by drawing regions of interests and using established cutoff thresholds. Skeletal muscle index (SMI), steatotic muscle area, and adipose tissue index, as well as muscle attenuation and fat attenuation, were evaluated.
RESULTS: Average SMI increased by up to 2.8% after contrast media injection. Steatotic muscle area decreased by ≤13.8%, and adipose tissue index decreased by ≤6.5%. Muscle attenuation increased after contrast media injection, whereas fat attenuation decreased (all P < 0.001). SMI decreased by 1.9% on average when increasing slice thickness from 2 to 10 mm. Steatotic muscle area increased by ≤3.3%, and adipose tissue index increased by ≤1.5% (all P < 0.05). Muscle attenuation did not change significantly with reconstruction thickness. Radiation dose had no effect on estimated area of spinal muscle, fatty spinal muscle, or visceral fat.
CONCLUSIONS: Contrast media have a strong effect on the evaluation of body composition, whereas the influence of slice thickness is less pronounced. Radiation dose can be reduced by ≥66% without significantly affecting segmentation.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app