JOURNAL ARTICLE
MULTICENTER STUDY
Add like
Add dislike
Add to saved papers

Impact of aortic stent-graft oversizing on outcomes of the chimney endovascular technique based on a new analysis of the PERICLES Registry.

Vascular 2019 April
OBJECTIVE: Chimney endovascular aortic aneurysm repair is gaining ever greater acceptance. However, persistent gutters leading to type IA endoleaks represent an unsolved issue. The aim of the current study was to analyze the impact of abdominal endograft oversizing to the occurrence of this phenomenon.

METHODS: The PERformance of the snorkel/chImney endovascular teChnique in the treatment of compLex aortic PathologiesES registry includes the largest experience with chimney endovascular aortic aneurysm repair from 13 vascular centers in Europe and the U.S. Prospectively collected data from centers with standard use of the Endurant stent-graft and balloon-expandable covered stents as chimney grafts only were included in the present analysis. The parameter which varied was the degree of oversizing of the aortic stent-graft classifying the cohort in two groups, group A (20% and less oversizing) and group B (>20% of oversizing). The primary endpoint was the incidence of persistent type IA endoleak needed reintervention. Secondary endpoints were all-cause mortality and freedom from reintervention.

RESULTS: Group A included 21 patients while group B 144. The mean preoperative pathology's neck length and diameter was 5.8 mm (±4.4) versus 4.9 mm (±3.8) and 27.6 mm (±4.7) versus 24.9 mm (±3.7) for group A and group B, respectively. The mean length of the new sealing zone after chimney graft placement was similar for both groups (group A versus group B; 17.9 mm versus 18.3 mm, respectively, P = .21). The percentage of oversizing of the aortic stent-graft ranged between 13.8 and 20% versus 22.2 and 30%, for group A and group B, respectively. Patients of group A had more type 1A endoleaks, (14.3%) versus patients of group B (2.1%) based on the first follow-up imaging, P = .02. The incidence of persistent type IA endoleaks needing a reintervention was 14.3 and 1.4% for the group A and group B, respectively, P = .01. The mean volume of contrast medium used was greater in group A versus group B with 239 ml versus150 ml, P = .05. Additionally, 14.3% of patients of group A experienced acute renal failure compared to those in group B which was 1.0%, P = .01.

CONCLUSIONS: Oversizing of ideally 30% of the Endurant stent-graft is associated with significant lower incidence of type IA endoleaks requiring reintervention for patients treated by chimney endovascular aortic aneurysm repair.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app