We have located links that may give you full text access.
Set screw homogenization of murine ocular tissue, including the whole eye.
Molecular Vision 2018
Purpose: To compare methods for homogenizing the mouse whole eye or retina for RNA extraction.
Methods: We tested five homogenization techniques for the whole eye and the retina. Two established shearing techniques were a version of the Potter-Elvehjem homogenizer, which uses a plastic pellet pestle in a microfuge tube, and a Dounce homogenizer. Two modern bead-beating methods used commercially manufactured devices, the Next Advance Bullet Blender and the Qiagen TissueLyser LT. The last method involved vortex mixing multiple samples simultaneously in a buffer containing a stainless-steel set screw, a novel approach. RNA was extracted from the tissue after each technique was used. Degradation of RNA was measured with the RNA integrity number (RIN score) after electrophoresis on an Agilent BioAnalyzer RNA LabChip. Nucleic acid yields were measured with ultraviolet (UV) spectroscopy in a BioTek Synergy H1 Hybrid plate reader. The purity of the nucleic acids was assessed with the mean absorbance ratio (A260 /A280 ). The preparation time per sample was measured with a digital stopwatch. Costs of necessary consumables were calculated per ten samples.
Results: The RIN scores for all homogenization methods and both tissue types ranged from 7.75±0.64 to 8.78±0.18; none were statistically significantly different. The total RNA yield per whole eye from the bead-based methods ranged from 7,700 to 9,800 ng and from 3,000 to 4,600 ng for the pellet pestle and Dounce shearing methods, respectively. The total RNA yield per retina from the bead-based methods ranged from 4,600 to 8,400 ng and from 2,200 to 7,400 ng for the pellet pestle and Dounce shearing methods, respectively. Homogenization was faster using the bead-based methods (about 15 min for ten samples) because multiple samples could be run simultaneously compared to the shearing methods that require samples be homogenized individually (about 45-60 min per ten samples). The costs in consumables for the methods tested ranged from $2.60 to $14.70 per ten samples. The major differences in overall costs come in the form of one-time equipment purchases, which can range from one hundred to thousands of dollars. The bead-based methods required less technician involvement and had less potential for sample contamination than the shearing methods.
Conclusions: The purity and quality of RNA were similar across all methods for both tissue types. The novel set screw method and the two bead-based methods (bullet blender and TissueLyser) outperformed the two shearing methods (the pellet pestle and Dounce techniques) in total RNA yields for the whole eye. Although the bullet blender, TissueLyser, and set screw methods produced comparable levels of RNA yield, purity, and quality, the set screw method was less expensive. Researchers seeking the efficiency of sophisticated bead homogenization equipment without the high equipment costs might consider this novel method.
Methods: We tested five homogenization techniques for the whole eye and the retina. Two established shearing techniques were a version of the Potter-Elvehjem homogenizer, which uses a plastic pellet pestle in a microfuge tube, and a Dounce homogenizer. Two modern bead-beating methods used commercially manufactured devices, the Next Advance Bullet Blender and the Qiagen TissueLyser LT. The last method involved vortex mixing multiple samples simultaneously in a buffer containing a stainless-steel set screw, a novel approach. RNA was extracted from the tissue after each technique was used. Degradation of RNA was measured with the RNA integrity number (RIN score) after electrophoresis on an Agilent BioAnalyzer RNA LabChip. Nucleic acid yields were measured with ultraviolet (UV) spectroscopy in a BioTek Synergy H1 Hybrid plate reader. The purity of the nucleic acids was assessed with the mean absorbance ratio (A260 /A280 ). The preparation time per sample was measured with a digital stopwatch. Costs of necessary consumables were calculated per ten samples.
Results: The RIN scores for all homogenization methods and both tissue types ranged from 7.75±0.64 to 8.78±0.18; none were statistically significantly different. The total RNA yield per whole eye from the bead-based methods ranged from 7,700 to 9,800 ng and from 3,000 to 4,600 ng for the pellet pestle and Dounce shearing methods, respectively. The total RNA yield per retina from the bead-based methods ranged from 4,600 to 8,400 ng and from 2,200 to 7,400 ng for the pellet pestle and Dounce shearing methods, respectively. Homogenization was faster using the bead-based methods (about 15 min for ten samples) because multiple samples could be run simultaneously compared to the shearing methods that require samples be homogenized individually (about 45-60 min per ten samples). The costs in consumables for the methods tested ranged from $2.60 to $14.70 per ten samples. The major differences in overall costs come in the form of one-time equipment purchases, which can range from one hundred to thousands of dollars. The bead-based methods required less technician involvement and had less potential for sample contamination than the shearing methods.
Conclusions: The purity and quality of RNA were similar across all methods for both tissue types. The novel set screw method and the two bead-based methods (bullet blender and TissueLyser) outperformed the two shearing methods (the pellet pestle and Dounce techniques) in total RNA yields for the whole eye. Although the bullet blender, TissueLyser, and set screw methods produced comparable levels of RNA yield, purity, and quality, the set screw method was less expensive. Researchers seeking the efficiency of sophisticated bead homogenization equipment without the high equipment costs might consider this novel method.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.