We have located links that may give you full text access.
Evaluation of a near-zero fluoroscopic approach for catheter ablation in patients with congenital heart disease.
Journal of Interventional Cardiac Electrophysiology : An International Journal of Arrhythmias and Pacing 2018 October 31
PURPOSE: Radiation exposure (RE) is a matter of concern for patients with congenital heart disease (CHD) who not infrequently need multiple interventional procedures under fluoroscopy guidance. We sought to evaluate the safety and feasibility of a minimally fluoroscopic approach in patients with CHD undergoing catheter ablation using a new image integration module (IIM).
METHODS: Consecutive patients with CHD undergoing catheter ablation using the Carto Univu™ IIM were included. A near-zero fluoroscopy procedure was defined by an effective dose (ED) ≤ 1 mSv. RE parameters (total fluoroscopy time [TFT], total dose area product [tDAP], and ED), ablation outcomes, and complications were evaluated.
RESULTS: Fifty-five patients with CHD underwent 63 ablation procedures (supraventricular tachycardia, n = 53; ventricular tachycardia, n = 10). The CHD was simple in 25%, moderate in 42%, and complex in 33%. The use of the IIM resulted in very low levels of RE (median TFT 0.13 min [IQR 0-1.04], median tDAP 54.5 cGy cm2 [IQR 9.5-176.4], median ED 0.136 mSv [IQR 0.02-0.49]). Patients with complex CHD had significantly higher RE when compared with patients with simple and moderate defects. A total of 56/63 ablation procedures (89%) were performed with an ED ≤ 1 mSv. One patient developed sinus node dysfunction requiring pacemaker implantation.
CONCLUSIONS: The use of a minimally fluoroscopic approach was safe and feasible resulting in very low RE during catheter ablation of patients with CHD. A near-zero fluoroscopy ablation was possible in up to 89% of the procedures.
METHODS: Consecutive patients with CHD undergoing catheter ablation using the Carto Univu™ IIM were included. A near-zero fluoroscopy procedure was defined by an effective dose (ED) ≤ 1 mSv. RE parameters (total fluoroscopy time [TFT], total dose area product [tDAP], and ED), ablation outcomes, and complications were evaluated.
RESULTS: Fifty-five patients with CHD underwent 63 ablation procedures (supraventricular tachycardia, n = 53; ventricular tachycardia, n = 10). The CHD was simple in 25%, moderate in 42%, and complex in 33%. The use of the IIM resulted in very low levels of RE (median TFT 0.13 min [IQR 0-1.04], median tDAP 54.5 cGy cm2 [IQR 9.5-176.4], median ED 0.136 mSv [IQR 0.02-0.49]). Patients with complex CHD had significantly higher RE when compared with patients with simple and moderate defects. A total of 56/63 ablation procedures (89%) were performed with an ED ≤ 1 mSv. One patient developed sinus node dysfunction requiring pacemaker implantation.
CONCLUSIONS: The use of a minimally fluoroscopic approach was safe and feasible resulting in very low RE during catheter ablation of patients with CHD. A near-zero fluoroscopy ablation was possible in up to 89% of the procedures.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app