Multicenter derivation and validation of an early warning score for acute respiratory failure or death in the hospital.
Critical Care : the Official Journal of the Critical Care Forum 2018 October 31
BACKGROUND: Acute respiratory failure occurs frequently in hospitalized patients and often starts before ICU admission. A risk stratification tool to predict mortality and risk for mechanical ventilation (MV) may allow for earlier evaluation and intervention. We developed and validated an automated electronic health record (EHR)-based model-Accurate Prediction of Prolonged Ventilation (APPROVE)-to identify patients at risk of death or respiratory failure requiring >= 48 h of MV.
METHODS: This was an observational study of adults admitted to four hospitals in 2013 or a fifth hospital in 2017. Clinical data were extracted from the EHRs. The 2013 patients were randomly split 50:50 into a derivation/validation cohort. The qualifying event was death or intubation leading to MV >= 48 h. Random forest method was used in model derivation. APPROVE was calculated retrospectively whenever data were available in 2013, and prospectively every 4 h after hospital admission in 2017. The Modified Early Warning Score (MEWS) and National Early Warning Score (NEWS) were calculated at the same times as APPROVE. Clinicians were not alerted except for APPROVE in 2017cohort.
RESULTS: There were 68,775 admissions in 2013 and 2258 in 2017. APPROVE had an area under the receiver operator curve of 0.87 (95% CI 0.85-0.88) in 2013 and 0.90 (95% CI 0.84-0.95) in 2017, which is significantly better than the MEWS and NEWS in 2013 but similar to the MEWS and NEWS in 2017. At a threshold of > 0.25, APPROVE had similar sensitivity and positive predictive value (PPV) (sensitivity 63% and PPV 21% in 2013 vs 64% and 16%, respectively, in 2017). Compared to APPROVE in 2013, at a threshold to achieve comparable PPV (19% at MEWS > 4 and 22% at NEWS > 6), the MEWS and NEWS had lower sensitivity (16% for MEWS and NEWS). Similarly in 2017, at a comparable sensitivity threshold (64% for APPROVE > 0.25 and 67% for MEWS and NEWS > 4), more patients who triggered an alert developed the event with APPROVE (PPV 16%) while achieving a lower false positive rate (FPR 5%) compared to the MEWS (PPV 7%, FPR 14%) and NEWS (PPV 4%, FPR 25%).
CONCLUSIONS: An automated EHR model to identify patients at high risk of MV or death was validated retrospectively and prospectively, and was determined to be feasible for real-time risk identification.
TRIAL REGISTRATION: ClinicalTrials.gov, NCT02488174 . Registered on 18 March 2015.
METHODS: This was an observational study of adults admitted to four hospitals in 2013 or a fifth hospital in 2017. Clinical data were extracted from the EHRs. The 2013 patients were randomly split 50:50 into a derivation/validation cohort. The qualifying event was death or intubation leading to MV >= 48 h. Random forest method was used in model derivation. APPROVE was calculated retrospectively whenever data were available in 2013, and prospectively every 4 h after hospital admission in 2017. The Modified Early Warning Score (MEWS) and National Early Warning Score (NEWS) were calculated at the same times as APPROVE. Clinicians were not alerted except for APPROVE in 2017cohort.
RESULTS: There were 68,775 admissions in 2013 and 2258 in 2017. APPROVE had an area under the receiver operator curve of 0.87 (95% CI 0.85-0.88) in 2013 and 0.90 (95% CI 0.84-0.95) in 2017, which is significantly better than the MEWS and NEWS in 2013 but similar to the MEWS and NEWS in 2017. At a threshold of > 0.25, APPROVE had similar sensitivity and positive predictive value (PPV) (sensitivity 63% and PPV 21% in 2013 vs 64% and 16%, respectively, in 2017). Compared to APPROVE in 2013, at a threshold to achieve comparable PPV (19% at MEWS > 4 and 22% at NEWS > 6), the MEWS and NEWS had lower sensitivity (16% for MEWS and NEWS). Similarly in 2017, at a comparable sensitivity threshold (64% for APPROVE > 0.25 and 67% for MEWS and NEWS > 4), more patients who triggered an alert developed the event with APPROVE (PPV 16%) while achieving a lower false positive rate (FPR 5%) compared to the MEWS (PPV 7%, FPR 14%) and NEWS (PPV 4%, FPR 25%).
CONCLUSIONS: An automated EHR model to identify patients at high risk of MV or death was validated retrospectively and prospectively, and was determined to be feasible for real-time risk identification.
TRIAL REGISTRATION: ClinicalTrials.gov, NCT02488174 . Registered on 18 March 2015.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app