Perceptions and Practice Patterns of Holmium Laser Goggles in Endourological Procedures: An Unnecessary Evil?

Journal of Endourology 2019 Februrary
PURPOSE: The holmium laser is used increasingly for a wide array of urological procedures. Laser safety goggles are mandatory at many centers for individuals within the nominal hazard zone, as set out by the institution. Recent ex vivo studies suggest standard eye wear may be equally as protective. We sought to evaluate the perceptions and practice patterns of laser safety goggles in urology.

MATERIALS AND METHODS: A 24-question survey was sent out through e-mail to an international e-mail list of ∼2000 urologists that were members of the Endourological Society. Data were collected anonymously using Survey Monkey.

RESULTS: A total of 264 (14%) urologists completed the survey. Thirty-four percent worked in the community, whereas 63% worked at an academic institution. Ninety-seven percent routinely used the holmium laser. The most common uses were lithotripsy (99%), tissue incision (71%), tumor ablation (58%), and prostate ablation (26%). Formal laser training and institutional laser safety policies were reported in 76% and 64%, respectively. Forty percent of respondents routinely wore laser safety goggles. Laser adverse events were witnessed by 19%, but there were no eye injuries reported. Seventy percent of surgeons felt that laser safety goggles may impair their vision. When presented with the information that regular eye glasses may be as effective as laser goggles for preventing harm, the majority (86%) would opt for regular eye wear.

CONCLUSIONS: Laser safety eyewear practice patterns vary greatly. Many centers have adopted policies for universal mandatory laser goggles in the operating room. With over two thirds of surgeons suggesting laser goggles impair their vision, and recent literature suggesting regular eye wear is equivalent in preventing laser-associated eye injuries, laser goggle safety policies should be updated to better match the potential hazards inherent to the device.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app