Add like
Add dislike
Add to saved papers

Long-term results of an anatomically implanted hip arthroplasty with a short stem prosthesis (MiniHip TM ).

AIM: To evaluate the clinical and radiological outcome nine and ten years after short-stemmed, bone preserving and anatomical hip arthroplasty with the MiniHipTM system.

METHODS: In a prospective study, 186 patients underwent hip arthroplasty with a partial neck preserving short stem (MiniHipTM , Corin). Elderly patients were not excluded from this study, thus the mean age at the time of surgery was 59.3 years (range 32 to 82 years). Surgery and the follow-up assessments were performed at two Centers. Up until now, the mean follow-up was 112.5 ± 8.2 mo. The Oxford Hip Score (OHS) and the Hip Dysfunction Osteoarthritis and Outcome Score (HOOS) was assessed pre- and each year after surgery. The clinical follow-up was accompanied by standardized a.p. and axial radiological examinations. Periprosthetic lucencies, hypertrophies within the Gruen zones one to fourteen were assessed. A subsidence of the stem was investigated according to Morray and heterotopic ossifications were assessed according to Brooker.

RESULTS: The OHS and HOOS improved from 18 ± 3.3 to 46 ± 2.0 and from 30 ± 8.3 to 95 ± 4.6 points, P < 0.001 respectively. There were no differences regarding age, etiology, friction pairings, etc ., ( P > 0.05). Two stems were revised due to a symptomatic subsidence four and twelve months postoperatively. Thus, the survivorship for aseptic loosening at nine to ten years was 98.66%. Including one stem revision due to a symptomatic exostosis, bursitis and thigh pain as well as one revision because of a septic stem loosening, the overall survival for the stem with revision for any reason was 97.32%. Besides one asymptomatic patient, radiological signs of a proximal stress-shielding, such as bone resorptions within the proximal Gruen zones, were not noticed. Findings suggesting a distal loading, e.g ., bony hypertrophies or bone appositions of more than 2 mm, were also not detected.

CONCLUSION: Regarding these first long-term results on the MiniHipTM , the implant performed exceedingly well with a high rate of survivorship for aseptic loosening. Our radiological results within the Gruen zones support the design rationale of the Minihip to provide a reliable metaphyseal anchoring with the expected proximal, more physiological load transfer. This might minimize or exclude a stress shielding which might be associated with thigh pain, proximal bone loss and an increased risk of aseptic loosening. The MiniHipTM is a reliable partial-neck retaining prosthesis with good a clinical long-term outcome in younger as well as elderly patients.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app