We have located links that may give you full text access.
JOURNAL ARTICLE
PRAGMATIC CLINICAL TRIAL
Does ultrasound guidance for peripherally inserted central catheter (PICC) insertion reduce the incidence of tip malposition? - a randomized trial.
OBJECTIVE: The aim of the study was to evaluate the incidence of peripheral inserted central catheter (PICC) tip malposition when the catheter is inserted under real-time ultrasound (RTUS) guidance when compared with conventional landmark (CL) technique in neonates. Additional objectives were to evaluate the PICC longevity and central line associated blood stream infections (CLABSI).
STUDY DESIGN: In this randomised controlled trial, neonates were randomised to 'RTUS' (n = 40) or 'CL' (n = 40) groups. PICC tip was placed under ultrasound guidance in lower third of superior vena cava in the RTUS group. In 'CL' group, PICC was inserted as calculated by anatomical landmarks.
RESULTS: The birth weight (1286 (926, 1662) vs. 1061 (889, 1636) g) and gestation (31.12 (3.1) vs. 31.4 (3.6) wks) were comparable among the groups. RTUS guidance during PICC insertion reduced incidence of tip malposition by 52% (67.5 vs. 32.5%; RR: 0.48; 95% CI: 0.29-0.79). The longevity of PICC and episodes of CLABSI were however similar in the two groups.
CONCLUSIONS: Real-time ultrasound guidance during PICC placement reduces the incidence of tip malposition.
STUDY DESIGN: In this randomised controlled trial, neonates were randomised to 'RTUS' (n = 40) or 'CL' (n = 40) groups. PICC tip was placed under ultrasound guidance in lower third of superior vena cava in the RTUS group. In 'CL' group, PICC was inserted as calculated by anatomical landmarks.
RESULTS: The birth weight (1286 (926, 1662) vs. 1061 (889, 1636) g) and gestation (31.12 (3.1) vs. 31.4 (3.6) wks) were comparable among the groups. RTUS guidance during PICC insertion reduced incidence of tip malposition by 52% (67.5 vs. 32.5%; RR: 0.48; 95% CI: 0.29-0.79). The longevity of PICC and episodes of CLABSI were however similar in the two groups.
CONCLUSIONS: Real-time ultrasound guidance during PICC placement reduces the incidence of tip malposition.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app