Technical Note: U-net Generated Synthetic CT images for Magnetic Resonance Imaging-Only Prostate Intensity-Modulated Radiation Therapy Treatment Planning.

Medical Physics 2018 October 21
PURPOSE: Clinical implementation of magnetic resonance imaging (MRI)-only radiotherapy requires a method to derive synthetic CT image (S-CT) for dose calculation. This study investigated the feasibility of building a deep convolutional neural network for MRI based S-CT generation and evaluate the dosimetric accuracy on prostate IMRT planning.

METHODS: A Paired CT and T2-weighted MR images were acquired from each of 51 prostate cancer patients. Fifteen pairs were randomly chosen as tested set and the remaining 36 pairs as training set. The training subjects were augmented by applying artificial deformations and feed to a 2-dimensional U-net which contains 23 convolutional layers and 25.29 million trainable parameters. The U-net represents a nonlinear function with input an MR slice and output the corresponding S-CT slice. The mean absolute error (MAE) of Hounsfield unit (HU) between the true CT and S-CT images were used to evaluate the HU estimation accuracy. IMRT plans with dose 79.2Gy prescribed to the PTV were applied using the true CT images. The true CT images then were replaced by the S-CT images and the dose matrices were recalculated on the same plan and compared to the one obtained from the true CT using gamma index analysis and absolute point dose discrepancy.

RESULTS: The U-net was trained from scratch in 58.67 hours using a GP100-GPU. The computation time for generating a new S-CT volume image was 3.84~7.65 seconds. Within body, the (mean ± SD) of MAE was (29.96 ± 4.87) HU. The 1%/1mm and 2%/2mm gamma pass rates were over 98.03% and 99.36% respectively. The DVH parameters discrepancy was less than 0.87% and the maximum point dose discrepancy within PTV was less than 1.01% respect to the prescription.

CONCLUSION: The U-net can generate S-CT images from conventional MR image within seconds with high dosimetric accuracy for prostate IMRT plan. This article is protected by copyright. All rights reserved.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app