AIM: The lungs-and particularly the alveolar-capillary membrane-may be sensitive to continuous flow (CF) and pulmonary pressure alterations in heart failure (HF). We aimed to investigate long-term effects of CF pumps on respiratory function.

METHODS AND RESULTS: We conducted a retrospective study of patients with end-stage HF at our institution. We analysed pulmonary function tests [e.g. forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1 )] and diffusing capacity of the lung for carbon monoxide (DLCO ) from before and after left ventricular assist device (LVAD) implantation and compared them with invasive haemodynamic studies. Of the 274 patients screened, final study analysis involved 44 patients with end-stage HF who had CF LVAD implantation between 1 February 2007 and 31 December 2015 at our institution. These patients [mean (standard deviation, SD) age, 50 (9) years; male sex, n = 33, 75%] received either the HeartMate II (Thoratec Corp.) pump (77%) or the HeartWare (HeartWare International Inc.) pump. The mean (SD) left ventricular ejection fraction was 21% (13%). At a median of 237 days post-LVAD implantation, we observed significant DLCO decrease (-23%) since pre-implantation (P < 0.001). ΔDLCO had an inverse relationship with changes in pulmonary capillary wedge pressure (PCWP) and right atrial pressure (RAP) from pre-LVAD to post-LVAD implantation: ΔDLCO to ΔPCWP (r = 0.50, P < 0.01) and ΔDLCO to ΔRAP (r = 0.39, P < 0.05). We observed other reductions in FEV1 , FVC, and FEV1 /FVC between pre-LVAD and post-LVAD implantation. In mean (SD) values, FEV1 changed from 2.3 (0.7) to 2.1 (0.7) (P = 0.005); FVC decreased from 3.2 (0.8) to 2.9 (0.9) (P = 0.01); and FEV1 /FVC went from 0.72 (0.1) to 0.72 (0.1) (P = 0.50). Landmark survival analysis revealed that ΔDLCO from 6 months after LVAD implantation was predictive of death for HF patients [hazard ratio (95% confidence interval), 0.60 (0.28-0.98); P = 0.03].

CONCLUSIONS: Pulmonary function did not improve after LVAD implantation. The degree of DLCO deterioration is related to haemodynamic status post-LVAD implantation. The ΔDLCO within 6 months post-operative was associated with survival.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app