We have located links that may give you full text access.
JOURNAL ARTICLE
RANDOMIZED CONTROLLED TRIAL
Comparison of blind intubation via supraglottic airway devices versus standard intubation during different airway emergency scenarios in inexperienced hand: Randomized, crossover manikin trial.
Medicine (Baltimore) 2018 October
BACKGROUND: Securing the airway and enabling adequate oxygenation and ventilation is essential during cardiopulmonary resuscitation (CPR). The aim of the study was to evaluate the success rate of blind intubation via the I-Gel and the Air-Q compared with direct laryngoscopy guided endotracheal intubation by inexperienced physician and to measure time to successful intubation.
METHODS: The study was designed as a randomized, cross-over simulation study. A total of 134 physicians, from specialties other than Anesthesia or Emergency Medicine, who considered themselves skilled in endotracheal intubation but who have never used any kind of supraglottic airway device performed blind intubation via the I-Gel and Air-Q and direct laryngoscopy guided endotracheal intubation in 3 randomized scenarios: normal airway without chest compression during intubation attempt; normal airway with continuous chest compression during intubation attempt; difficult airway with continuous chest compression.
RESULTS: Scenario A: Success rate with initial intubation attempt was 72% for endotracheal intubation, 75% in Air-Q, and 81% in I-Gel. Time to endotracheal intubation and ease of intubation was comparable with all 3 airway devices used. Scenario B: Success rate with the initial intubation attempt was 42% for endotracheal intubation, compared with 75% in Air-Q and 80% in I-Gel. Time for endotracheal intubation was significantly prolonged in endotracheal intubation (42 seconds, 35-49), compared with Air-Q (21 seconds, 18-32) and I-Gel (19 seconds, 17-27). Scenario C: The success rate with the initial intubation attempt was 23% in endotracheal intubation, compared with 65% in Air-Q and 74% in I-Gel. Time to intubation was comparable with both supraglottic airway devices (20 vs 22 seconds) but was significantly shorter compared with endotracheal intubation (50 seconds, P < .001).
CONCLUSIONS: Less to moderately experienced providers are able to perform endotracheal intubation in easy airways but fail during ongoing chest compressions and simulated difficult airway. Consequently, less to moderately experienced providers should refrain from endotracheal intubation during ongoing chest compressions during CPR and in expected difficult airways. Supraglottic airway devices are reliable alternatives and blind intubation through these devices is a valuable airway management strategy.
METHODS: The study was designed as a randomized, cross-over simulation study. A total of 134 physicians, from specialties other than Anesthesia or Emergency Medicine, who considered themselves skilled in endotracheal intubation but who have never used any kind of supraglottic airway device performed blind intubation via the I-Gel and Air-Q and direct laryngoscopy guided endotracheal intubation in 3 randomized scenarios: normal airway without chest compression during intubation attempt; normal airway with continuous chest compression during intubation attempt; difficult airway with continuous chest compression.
RESULTS: Scenario A: Success rate with initial intubation attempt was 72% for endotracheal intubation, 75% in Air-Q, and 81% in I-Gel. Time to endotracheal intubation and ease of intubation was comparable with all 3 airway devices used. Scenario B: Success rate with the initial intubation attempt was 42% for endotracheal intubation, compared with 75% in Air-Q and 80% in I-Gel. Time for endotracheal intubation was significantly prolonged in endotracheal intubation (42 seconds, 35-49), compared with Air-Q (21 seconds, 18-32) and I-Gel (19 seconds, 17-27). Scenario C: The success rate with the initial intubation attempt was 23% in endotracheal intubation, compared with 65% in Air-Q and 74% in I-Gel. Time to intubation was comparable with both supraglottic airway devices (20 vs 22 seconds) but was significantly shorter compared with endotracheal intubation (50 seconds, P < .001).
CONCLUSIONS: Less to moderately experienced providers are able to perform endotracheal intubation in easy airways but fail during ongoing chest compressions and simulated difficult airway. Consequently, less to moderately experienced providers should refrain from endotracheal intubation during ongoing chest compressions during CPR and in expected difficult airways. Supraglottic airway devices are reliable alternatives and blind intubation through these devices is a valuable airway management strategy.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university