A multi-center evaluation of a disposable catheter to aid in correct positioning of the endotracheal tube after intubation in critically ill patients.
Journal of Critical Care 2018 September 7
PURPOSE: To demonstrate that use of a minimally invasive catheter reduces endotracheal tube (ETT) malposition rate after intubation.
MATERIALS AND METHODS: This study is a multi-center, prospective observational cohort of intubated patients in the medical intensive care unit. The catheter was inserted into the ETT immediately after intubation. The ETT was adjusted accordingly based on qualitative color markers on the catheter. A confirmatory chest radiograph was obtained to determine the ETT position. Malposition of the ETT was defined by the distal ETT not being within 2-5 cm above the carina.
RESULTS: Sixty-nine patients were enrolled, age 56.2 ± 19.5 years, body mass index 31.0 ± 13.8 kg/m2 . The catheter prompted repositioning of the ETT in 39 (56.5%) patients. Using the catheter, the rate of malposition decreased to 7.2%, with the distal ETT position at 3.7 ± 1.2 cm above the carina. Without the catheter, the ETT malposition rate would have been 39.1%. The time for catheter use and chest radiograph completion at our institutions was 1.7 ± 1.5 and 44.4 ± 36.4 min, respectively.
CONCLUSIONS: With use of an ETT positioning catheter after intubation, the ETT malposition rate was reduced by 82%. This catheter-based system was safe, and its use may perhaps decrease the need for the post-intubation chest radiograph.
MATERIALS AND METHODS: This study is a multi-center, prospective observational cohort of intubated patients in the medical intensive care unit. The catheter was inserted into the ETT immediately after intubation. The ETT was adjusted accordingly based on qualitative color markers on the catheter. A confirmatory chest radiograph was obtained to determine the ETT position. Malposition of the ETT was defined by the distal ETT not being within 2-5 cm above the carina.
RESULTS: Sixty-nine patients were enrolled, age 56.2 ± 19.5 years, body mass index 31.0 ± 13.8 kg/m2 . The catheter prompted repositioning of the ETT in 39 (56.5%) patients. Using the catheter, the rate of malposition decreased to 7.2%, with the distal ETT position at 3.7 ± 1.2 cm above the carina. Without the catheter, the ETT malposition rate would have been 39.1%. The time for catheter use and chest radiograph completion at our institutions was 1.7 ± 1.5 and 44.4 ± 36.4 min, respectively.
CONCLUSIONS: With use of an ETT positioning catheter after intubation, the ETT malposition rate was reduced by 82%. This catheter-based system was safe, and its use may perhaps decrease the need for the post-intubation chest radiograph.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app