In-vitro validation of 4D flow MRI measurements with an experimental pulsatile flow model.
Diagnostic and Interventional Imaging 2018 September 19
PURPOSE: The purpose of this study was to assess the precision of four-dimensional (4D) phase-contrast magnetic resonance imaging (PCMRI) to measure mean flow and peak velocity (Vmax ) in a pulsatile flow phantom and to test its sensitivity to spatial resolution and Venc.
MATERIAL AND METHODS: The pulsatile flow phantom consisted of a straight tube connected to the systemic circulation of an experimental mock circulatory system. Four-dimensional-PCMR images were acquired using different spatial resolutions (minimum pixel size: 1.5×1.5×1.5mm3 ) and velocity encoding sensitivities (up to three times Vmax ). Mean flow and Vmax calculated from 4D-PCMRI were compared respectively to the reference phantom flow parameters and to Vmax obtained from two-dimensional (2D)-PCMRI.
RESULTS: 4D-PCI measured mean flow with a precision of -0.04% to+5.46%, but slightly underestimated Vmax when compared to 2D-PCMRI (differences ranging from -1.71% to -3.85%). 4D PCMRI mean flow measurement was influenced by spatial resolution (P<0.001) with better results obtained with smaller voxel size. There was no effect of Venc on mean flow measurement. Regarding Vmax , neither spatial resolution nor Venc did influence the precision of the measurement.
CONCLUSION: Using an experimental pulsatile flow model 4D-PCMRI is accurate to measure mean flow and Vmax with better results obtained with higher spatial resolution. We also show that Venc up to 3 times higher than Vmax may be used with no effect on these measurements.
MATERIAL AND METHODS: The pulsatile flow phantom consisted of a straight tube connected to the systemic circulation of an experimental mock circulatory system. Four-dimensional-PCMR images were acquired using different spatial resolutions (minimum pixel size: 1.5×1.5×1.5mm3 ) and velocity encoding sensitivities (up to three times Vmax ). Mean flow and Vmax calculated from 4D-PCMRI were compared respectively to the reference phantom flow parameters and to Vmax obtained from two-dimensional (2D)-PCMRI.
RESULTS: 4D-PCI measured mean flow with a precision of -0.04% to+5.46%, but slightly underestimated Vmax when compared to 2D-PCMRI (differences ranging from -1.71% to -3.85%). 4D PCMRI mean flow measurement was influenced by spatial resolution (P<0.001) with better results obtained with smaller voxel size. There was no effect of Venc on mean flow measurement. Regarding Vmax , neither spatial resolution nor Venc did influence the precision of the measurement.
CONCLUSION: Using an experimental pulsatile flow model 4D-PCMRI is accurate to measure mean flow and Vmax with better results obtained with higher spatial resolution. We also show that Venc up to 3 times higher than Vmax may be used with no effect on these measurements.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app