Sub-endocardial and sub-epicardial measurement of myocardial blood flow using 13 NH 3 PET in man.

BACKGROUND: This study examined whether measuring myocardial blood flow (MBF) in the sub-endocardial (SEN) and sub-epicardial (SEP) layers of the left ventricular myocardium using 13 NH3 positron emission tomography (PET) and an automated procedure gives reasonable results in patients with known or suspected coronary artery disease (CAD).

METHODS: Resting and stress 13 NH3 dynamic PET were performed in 70 patients. Using ≥ 70% diameter stenosis in invasive coronary angiography (ICA) to identify significant CAD, we examined the diagnostic value of SEN- and SEP-MBF, and coronary flow reserve (CFR) vs. the corresponding conventional data averaged on the whole wall thickness.

RESULTS: ICA demonstrated 36 patients with significant CAD. Their global stress average [1.61 (1.26, 1.87) mL·min-1 ·g-1 ], SEN [1.39 (1.2, 1.59) mL·min-1 ·g-1 ] and SEP [1.22 (0.96, 1.44) mL·min-1 ·g-1 ] MBF were significantly lower than in the 34 no-CAD patients: 2.05 (1.76, 2.52), 1.72 (1.53, 1.89) and 1.46 (1.23, 1.89) mL·min-1 ·g-1 , respectively, all P < .005. In the 60 CAD vs. the 150 non-CAD territories, stress average MBF was 1.52 (1.10, 1.83) vs. 2.06 (1.69, 2.48) mL·min-1 ·g-1 , SEN-MBF 1.33 (1.02, 1.58) vs. 1.66 (1.35, 1.93) mL·min-1 ·g-1 , and SEP-MBF 1.07 (0.80, 1.29) vs. 1.40 (1.12, 1.69) mL·min-1 ·g-1 , respectively, all P < .05. Using receiver operating characteristics analysis for the presence of significant CAD, the areas under the curve (AUC) were all significant (P < .0001 vs. AUC = 0.5) and similar: stress average MBF = 0.79, SEN-MBF = 0.75, and SEP-MBF = 0.73. AUC was 0.77 for the average CFR, 0.75 for SEN, and 0.70 for SEP CFR. The stress transmural perfusion gradient (TPG) AUC (0.51) was not significant. However, stress TPG was significantly lower in segments subtended by totally occluded arteries vs. those subtended by sub-total stenoses: 1.10 (0.86, 1.33) vs. 1.24 (0.98, 1.56), respectively, P < .005.

CONCLUSION: Automatic assessment of SEN- and SEP-MBF (and CFR) using 13 NH3 PET gives reasonable results that are in good agreement with the conventional average whole wall thickness data. Further studies are needed to examine the utility of layer measurements such as in patients with hibernating myocardium or microvascular disease.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app