Add like
Add dislike
Add to saved papers

A retained guidewire fractured with subsequent pericardial tamponade two years after endovascular neurointervention.

Entrapment of aneurysm embolization hardware is an extremely rare complication of endovascular neurointerventional procedures. We describe a case of a retained guidewire in a 42-year-old male during an aneurysm embolization. After unsuccessful attempts at removal via interventional methods, we decided to leave the guidewire within the vessel. A guidewire fracture resulted in several fragments in the carotid artery and aorta with subsequent cardiac tamponade, pseudoaneurysm and aortojejunal fistula two years later. The fragments in the aorta were removed via interventional and surgical methods. We advocate early surgical management of the retained guidewires after unsuccessful retractions via interventional methods. Meticulous and gentle maneuvering is necessary to prevent such serious complications.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app