Loop and knot security of a novel arthroscopic sliding-locking knot using high-strength sutures.

Objective: We evaluated the loop and knot security of a novel arthroscopic knot, the Wiese knot, using different types of sutures.

Methods: The Wiese knot was tied using four different brands of braided sutures (Ethibond, Orthocord, FiberWire, and UltraBraid) with and without a series of three reversing half-hitches (RHAPs) and tested for loop and knot security.

Results: Orthocord provided the greatest amount of loop security. FiberWire delivered the highest knot security. UltraBraid had the greatest ultimate force. Three half-hitches increased the maximal load to clinical failure.

Conclusion: The biomechanical characteristics of the Wiese knot are affected by suture material qualities.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app