The rotating stretched curved planar reconstruction of 3D-FIESTA MR imaging for evaluating the anterior cruciate ligament of the knee joint.

Magnetic Resonance Imaging 2018 September 15
PURPOSE: To determine the feasibility of the rotating stretched curved planar reconstruction (CPR) of three-dimensional fast imaging with steady-state acquisition magnetic resonance imaging (3D-FIESTA MRI) for evaluating the anterior cruciate ligament of the knee joint.

MATERIALS AND METHODS: MRI of 40 knee joints in healthy volunteers was performed on a 3.0-T MR scanner and a phased-array extremity coil. The protocol consisted of oblique sagittal spin echo (SE) T1WI, coronal FS-PDWI, axial FS-FSE-T2WI, and 3D-FIESTA sequences. The rotating stretched curved planar reconstructions (CPR) of the ACL at angles of 0°, 30°, 60°, 90°, 120°, 150°, and 180° were generated from images of 3D-FIESTA sequences. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the 3D-FIESTA were compared with those of the oblique sagittal SE T1WI sequence. The presence of the tibial attachment, midportion, femoral attachment, and double bundles of the ACL on the oblique sagittal SE T1WI and CPR of 3D-FIESTA MR imaging were divided into two categories: visible and not visible.

RESULTS: The ACL SNR efficiency of 3D-FIESTA sequences was significantly higher than that of oblique sagittal SE T1WI sequence (P < 0.05). The 3D-FIESTA sequences produced images with a significantly higher CNR between ACL and synovial fluid than did the oblique sagittal SE T1WI sequence (P < 0.05). CPR of 3D-FIESTA MRI generated an excellent visualization of the ACL. The CPR of 3D-FIESTA MRI was rated superior to oblique sagittal SE T1WI sequence in 60% and 65% of cases with regard to the tibial attachment and midportion of ACL, respectively (P < 0.05). CPR of 3D-FIESTA MR imaging was rated superior to oblique sagittal SE T1WI sequence in 80% and 85% of cases with regard to femoral attachment and double bundles of ACL, respectively (P < 0.05).

CONCLUSION: The rotating stretched curved planar reconstruction of 3D-FIESTA sequences is significantly better than that of conventional 2D-MRI in evaluating the native ACL and its components, AM bundle and PL bundle, in healthy volunteers.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app