Aim: The aim of this research is to establish if variation exists in the dose delivered for head and neck (HN) localisation computed tomography (CT) imaging in radiation therapy (RT); to propose a national diagnostic reference levels (DRLs) for this procedure and to make a comparison between the national DRL and a DRL of a European sample.
Background: CT has become an indispensable tool in radiotherapy (RT) treatment planning. It is a requirement of legislation in many countries that doses of ionising radiation for medical exposures be kept 'As Low As Reasonably Achievable'. There are currently no dose guidelines for RT localisation CT of the HN.
Materials and methods: All RT departments in Ireland and a sample of European departments were surveyed. Dose data on CT dose length product (DLP); dose index volume (CTDIvol); current time product; tube voltage and scan length was acquired for ten average-sized HN patients from each department. DRLs were proposed for DLP and CTDIvol using the rounded 75th percentile of the distribution of the means.
Results: 42% of Irish departments and one European department completed the survey. Significant variation was found in the mean DLP, CTDIvol and scan lengths across the Irish departments. The proposed Irish DRL is 882 mGy cm and 21 mGy and the European department DRL is 816 mGy cm and 21 mGy, for DLP and CTDIvol, respectively.
Conclusions: Variation exists in doses used for HN RT localisation CT. DRLs have been proposed for comparison purposes with the aim of dose optimisation.
Background: CT has become an indispensable tool in radiotherapy (RT) treatment planning. It is a requirement of legislation in many countries that doses of ionising radiation for medical exposures be kept 'As Low As Reasonably Achievable'. There are currently no dose guidelines for RT localisation CT of the HN.
Materials and methods: All RT departments in Ireland and a sample of European departments were surveyed. Dose data on CT dose length product (DLP); dose index volume (CTDIvol); current time product; tube voltage and scan length was acquired for ten average-sized HN patients from each department. DRLs were proposed for DLP and CTDIvol using the rounded 75th percentile of the distribution of the means.
Results: 42% of Irish departments and one European department completed the survey. Significant variation was found in the mean DLP, CTDIvol and scan lengths across the Irish departments. The proposed Irish DRL is 882 mGy cm and 21 mGy and the European department DRL is 816 mGy cm and 21 mGy, for DLP and CTDIvol, respectively.
Conclusions: Variation exists in doses used for HN RT localisation CT. DRLs have been proposed for comparison purposes with the aim of dose optimisation.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
Perioperative echocardiographic strain analysis: what anesthesiologists should know.Canadian Journal of Anaesthesia 2024 April 11
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app