We have located links that may give you full text access.
EVALUATION STUDIES
JOURNAL ARTICLE
Peripheral Lung Nodule Diagnosis and Fiducial Marker Placement Using a Novel Tip-Tracked Electromagnetic Navigation Bronchoscopy System.
Journal of Bronchology & Interventional Pulmonology 2019 January
BACKGROUND: Electromagnetic navigation (EMN) has improved bronchoscopic access to peripheral pulmonary nodules. A novel EMN system utilizing novel tip-tracked instruments for endobronchial [electromagnetic navigation bronchoscopy (ENB)] as well as transthoracic lung biopsy [electromagnetic-guided transthoracic needle aspiration (EMTTNA)] has become available. The system provides real-time feedback as well as the ability to biopsy lesions outside of the airway. These advances have the potential to improve diagnostic yield over previous EMN systems.
METHODS: We performed a retrospective review of consecutive peripheral bronchoscopy cases utilizing a novel EMN platform for biopsy and/or fiducial marker (FM) placement at a tertiary care university hospital. We analyzed factors that may influence diagnostic yield including lesion size.
RESULTS: Our study included 108 patients who underwent EMN-guided bronchoscopy between June 2015 and April 2017 for the diagnosis of peripheral lung lesions and/or the placement of FMs for stereotactic body radiotherapy. Ninety-three patients underwent biopsy utilizing ENB +/- EMTTNA. The combined diagnostic yield was 78%. EMTTNA provided a diagnosis for 5 patients in whom the ENB biopsy results were negative. Diagnostic yield by nodules <20, 20 to 30, and >30 mm in size was 30/45 (67%), 27/30 (90%), and 16/18 (89%), respectively. Sixty-five patients underwent FM placement with a total of 133 FM placed.
CONCLUSION: This novel tip-tracked EMN system incorporating both ENB and EMTTNA can guide biopsy and FM placement with a high degree of success and with a low complication rate. Multicentered prospective trials are required to develop algorithmic approaches to combine ENB and EMTTNA into a single procedure.
METHODS: We performed a retrospective review of consecutive peripheral bronchoscopy cases utilizing a novel EMN platform for biopsy and/or fiducial marker (FM) placement at a tertiary care university hospital. We analyzed factors that may influence diagnostic yield including lesion size.
RESULTS: Our study included 108 patients who underwent EMN-guided bronchoscopy between June 2015 and April 2017 for the diagnosis of peripheral lung lesions and/or the placement of FMs for stereotactic body radiotherapy. Ninety-three patients underwent biopsy utilizing ENB +/- EMTTNA. The combined diagnostic yield was 78%. EMTTNA provided a diagnosis for 5 patients in whom the ENB biopsy results were negative. Diagnostic yield by nodules <20, 20 to 30, and >30 mm in size was 30/45 (67%), 27/30 (90%), and 16/18 (89%), respectively. Sixty-five patients underwent FM placement with a total of 133 FM placed.
CONCLUSION: This novel tip-tracked EMN system incorporating both ENB and EMTTNA can guide biopsy and FM placement with a high degree of success and with a low complication rate. Multicentered prospective trials are required to develop algorithmic approaches to combine ENB and EMTTNA into a single procedure.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app