We have located links that may give you full text access.
Evaluation Studies
Journal Article
Convenient Method of Measuring Baseline Impedance for Distinguishing Patients with Functional Heartburn from those with Proton Pump Inhibitor-Resistant Endoscopic Negative Reflux Disease.
Digestion 2019
BACKGROUND: Combined 24-h intraesophageal pH-multichannel intraluminal impedance (24MII-pH) used for assessing gastroesophageal reflux disease by measuring baseline impedance (BI) requires a 24-h measuring period. In the present study, we developed a quick method of measuring BI and evaluated its usefulness in classifying patients with proton pump inhibitor (PPI)-refractory non-erosive reflux diseases (NERD) as having functional heartburn (FH) or endoscopic-negative reflux disease (ENRD).
METHODS: Ninety-one NERD patients without esophageal motility disorder underwent 24MII-pH monitoring while on a PPI. The measurements of the mean nocturnal BI (MNBI) and short MNBI were assessed at 3 times (at about 1: 00, 2: 00, and 3: 00 am) for 10 min and 30 s respectively. The measurement of the simple mean BI (MBI) was performed once 30 s at about 11: 00 am.
RESULTS: Ninety-one patients were divided into 2 groups: 59 with ENRD and 32 with FH. The cutoff, specificity, and sensitivity for distinguishing patients with FH were as follows: MNBI, 2,874.1 Ω, 72%, and 72%; short MNBI, 2,857.6 Ω, 74%, and 84%; and simple MBI, 2,874.1 Ω, 86%, and 78% respectively.
CONCLUSION: Measuring the simple MBI is a quick method and is useful for distinguishing patients with FH from those in a cohort with PPI-refractory NERD.
METHODS: Ninety-one NERD patients without esophageal motility disorder underwent 24MII-pH monitoring while on a PPI. The measurements of the mean nocturnal BI (MNBI) and short MNBI were assessed at 3 times (at about 1: 00, 2: 00, and 3: 00 am) for 10 min and 30 s respectively. The measurement of the simple mean BI (MBI) was performed once 30 s at about 11: 00 am.
RESULTS: Ninety-one patients were divided into 2 groups: 59 with ENRD and 32 with FH. The cutoff, specificity, and sensitivity for distinguishing patients with FH were as follows: MNBI, 2,874.1 Ω, 72%, and 72%; short MNBI, 2,857.6 Ω, 74%, and 84%; and simple MBI, 2,874.1 Ω, 86%, and 78% respectively.
CONCLUSION: Measuring the simple MBI is a quick method and is useful for distinguishing patients with FH from those in a cohort with PPI-refractory NERD.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app