We have located links that may give you full text access.
Variations in the Anatomic Morphology of the Lateral Distal Tibia: Surgical Implications for Distal Tibial Allograft Glenoid Reconstruction.
American Journal of Sports Medicine 2018 October
BACKGROUND: Distal tibial allograft glenoid augmentation has been introduced as a viable treatment approach for glenoid bone loss in conjunction with shoulder instability. No previous study, however, has assessed the morphologic variation of the distal tibia at the incisura as it relates to graft dimensions for glenoid augmentation. Increased concavity at the lateral distal tibia necessitates removal of the lateral cortex to obtain a flat surface, which may have implications for the strength of surgical fixation.
PURPOSE: To assess the morphologic variation of the distal tibia at the incisura as it relates to graft dimensions for glenoid augmentation.
STUDY DESIGN: Descriptive laboratory study.
METHODS: Magnetic resonance images of the ankle were reviewed for morphology assessment of the appearance and depth of the distal tibia. A classification system was created reflecting the suitability for glenoid augmentation. Type A tibias contained a flat contour of the lateral tibia at the articular surface, indicative of an ideal graft. Type B tibias had slight concavity with a central depth <5 mm and were deemed acceptable grafts. Type C tibias had deep concavity with a central depth >5 mm and were deemed unacceptable. Statistical analysis was performed via univariate analyses to compare patient demographics against acceptable morphology for glenoid augmentation.
RESULTS: Eighty-five study patients met inclusion criteria (53 male, 32 female; mean age ± SD, 35.1 ± 10.3 years). Overall, 12 patients (14.1%) demonstrated type A morphology, with 61 patients (71.8%) having type B morphology for a total of 85.9% of acceptable grafts for glenoid augmentation. The interrater reliability was moderate to strong between observers (kappa value = 0.841). On univariate analysis, sex was the only variable significantly associated with an acceptable graft, with 100% of female patients having acceptable morphology, as compared with 77% of male patients ( P = .004).
CONCLUSION: Variable morphology of the distal tibia at the incisura was found: 14.1% of patients demonstrated an ideal morphology for glenoid augmentation; an additional 71.8% were deemed suitable for graft usage; and 14.1% of tibias had unacceptable morphology. Sex was a significant factor for predicting acceptable grafts.
CLINICAL RELEVANCE: This information will assist surgeons in accepting or rejecting grafts based on the epidemiology of the distal tibial morphology as it relates to glenoid augmentation.
PURPOSE: To assess the morphologic variation of the distal tibia at the incisura as it relates to graft dimensions for glenoid augmentation.
STUDY DESIGN: Descriptive laboratory study.
METHODS: Magnetic resonance images of the ankle were reviewed for morphology assessment of the appearance and depth of the distal tibia. A classification system was created reflecting the suitability for glenoid augmentation. Type A tibias contained a flat contour of the lateral tibia at the articular surface, indicative of an ideal graft. Type B tibias had slight concavity with a central depth <5 mm and were deemed acceptable grafts. Type C tibias had deep concavity with a central depth >5 mm and were deemed unacceptable. Statistical analysis was performed via univariate analyses to compare patient demographics against acceptable morphology for glenoid augmentation.
RESULTS: Eighty-five study patients met inclusion criteria (53 male, 32 female; mean age ± SD, 35.1 ± 10.3 years). Overall, 12 patients (14.1%) demonstrated type A morphology, with 61 patients (71.8%) having type B morphology for a total of 85.9% of acceptable grafts for glenoid augmentation. The interrater reliability was moderate to strong between observers (kappa value = 0.841). On univariate analysis, sex was the only variable significantly associated with an acceptable graft, with 100% of female patients having acceptable morphology, as compared with 77% of male patients ( P = .004).
CONCLUSION: Variable morphology of the distal tibia at the incisura was found: 14.1% of patients demonstrated an ideal morphology for glenoid augmentation; an additional 71.8% were deemed suitable for graft usage; and 14.1% of tibias had unacceptable morphology. Sex was a significant factor for predicting acceptable grafts.
CLINICAL RELEVANCE: This information will assist surgeons in accepting or rejecting grafts based on the epidemiology of the distal tibial morphology as it relates to glenoid augmentation.
Full text links
Related Resources
Trending Papers
Challenges in Septic Shock: From New Hemodynamics to Blood Purification Therapies.Journal of Personalized Medicine 2024 Februrary 4
Molecular Targets of Novel Therapeutics for Diabetic Kidney Disease: A New Era of Nephroprotection.International Journal of Molecular Sciences 2024 April 4
The 'Ten Commandments' for the 2023 European Society of Cardiology guidelines for the management of endocarditis.European Heart Journal 2024 April 18
A Guide to the Use of Vasopressors and Inotropes for Patients in Shock.Journal of Intensive Care Medicine 2024 April 14
Diagnosis and Management of Cardiac Sarcoidosis: A Scientific Statement From the American Heart Association.Circulation 2024 April 19
Essential thrombocythaemia: A contemporary approach with new drugs on the horizon.British Journal of Haematology 2024 April 9
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app