We have located links that may give you full text access.
Effects of resterilization and storage time on sterility of paper/plastic pouches.
European Journal of Dentistry 2018 July
Objectives: Paper/plastic pouches are widely used packaging materials for autoclaving medical and dental equipment. Although these pouches are recommended for single use, they are generally reused in Thailand. This study aimed to determine the ability of paper/plastic pouches to maintain sterility after multiple sterilization processes and stored in a closed environment for up to 6 months.
Materials and Methods: A total of 6720 paper/plastic pouches were divided into four experimental groups: new pouches, 1 time, 3 times, and 5 times resterilized pouches. A piece of filter paper was placed inside each pouch, and the pouch was sealed, sterilized, and stored for up to 6 months. At the end of each storage period, the pouch was opened, and the filter paper was transferred to culture broth for microbial cultivation to determine sterility. Negative and positive controls were also used to validate the procedures.
Results: All filter papers in the experimental groups, as well as the negative control group, remained sterile for up to 6 months of storage in a closed environment. On the contrary, all filter papers in the positive control group showed microbial contamination.
Conclusions: In a closed storage condition, the paper/plastic pouches that passed multiple sterilization processes (up to 5 times resterilization) still maintained good barrier efficacy and remained sterile for up to 6 months.
Materials and Methods: A total of 6720 paper/plastic pouches were divided into four experimental groups: new pouches, 1 time, 3 times, and 5 times resterilized pouches. A piece of filter paper was placed inside each pouch, and the pouch was sealed, sterilized, and stored for up to 6 months. At the end of each storage period, the pouch was opened, and the filter paper was transferred to culture broth for microbial cultivation to determine sterility. Negative and positive controls were also used to validate the procedures.
Results: All filter papers in the experimental groups, as well as the negative control group, remained sterile for up to 6 months of storage in a closed environment. On the contrary, all filter papers in the positive control group showed microbial contamination.
Conclusions: In a closed storage condition, the paper/plastic pouches that passed multiple sterilization processes (up to 5 times resterilization) still maintained good barrier efficacy and remained sterile for up to 6 months.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app