Double Guided Surgery in All-on-4 ® Concept: When Ostectomy Is Needed.
Background: The rehabilitation of edentulous jaws with guided and flapless surgery applied to the All-on-4 concepts is a predictable treatment with a high implant and prosthetic survival rates, but there are several contraindications for this technique like when bone reduction is needed due to a high smile line in the maxilla or when there is an irregular or thin bone crest.
Purpose: To report a technique with double guided surgery for bone reduction and implant placement with the All-on-4 concept.
Materials and Methods: 7 patients were included in the study. Guided implant planning was performed using CBCT, and the virtual templates were created with three dedicated software. Custom surgical templates were made for the ostectomy and for implants positioning.
Results: 28 implants were placed using a double bone-supported surgical guide. The mean angular errors between the preoperative-planned implant and the postoperative-placed implant were 2.155° ± 2.03°; the mean distance errors between the planned and the placed implants were 0.763 mm ± 0.55 mm on the shoulder implant and 0.570 mm ± 0.40 mm on the apex implant.
Conclusions: The results of our study indicate that this treatment is predictable with an excellent survival rate allowing excellent results even when bone reduction is mandatory.
Purpose: To report a technique with double guided surgery for bone reduction and implant placement with the All-on-4 concept.
Materials and Methods: 7 patients were included in the study. Guided implant planning was performed using CBCT, and the virtual templates were created with three dedicated software. Custom surgical templates were made for the ostectomy and for implants positioning.
Results: 28 implants were placed using a double bone-supported surgical guide. The mean angular errors between the preoperative-planned implant and the postoperative-placed implant were 2.155° ± 2.03°; the mean distance errors between the planned and the placed implants were 0.763 mm ± 0.55 mm on the shoulder implant and 0.570 mm ± 0.40 mm on the apex implant.
Conclusions: The results of our study indicate that this treatment is predictable with an excellent survival rate allowing excellent results even when bone reduction is mandatory.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app