Patient response prediction with logistic regression in gastrointestinal endoscopy under midazolam-alfentanil sedation performed as well as response surface model.
Journal of the Chinese Medical Association : JCMA 2018 December
BACKGROUND: Researchers have used logistic regression (LR) and non-linear response surface models (RSMs) to predict patient responses to sedation. The reduced Greco and hierarchy RSMs have proven to be more appropriate than other RSMs in gastrointestinal endoscopies using midazolam and alfentanil. In this study, we evaluate the performance of a simpler model, LR, and compared it with that of RSM.
METHODS: Thirty-three patients who received esophagogastroduodenoscopy (EGD) and colonoscopy sedation with midazolam and alfentanil were enrolled in the study. LR was performed for the EGD group and validated using the colonoscopy group. The two RSMs were performed using the same process, and performances and receiver operating characteristic (ROC) curves of the models were evaluated.
RESULTS: The native EGD LR model had an ROC curve area of 0.94. For external validation, the ROC curves were 0.92, 0.94, and 0.94 for the reduced Greco, hierarchy, and LR models, respectively. Pairwise comparison between models was not significant.
CONCLUSION: The LR model performed as well as RSM in generalizing the predicted sedative effect of midazolam and alfentanil during gastrointestinal endoscopies. LR may be used for generalization across patients experiencing procedures with similar stimulus intensities.
METHODS: Thirty-three patients who received esophagogastroduodenoscopy (EGD) and colonoscopy sedation with midazolam and alfentanil were enrolled in the study. LR was performed for the EGD group and validated using the colonoscopy group. The two RSMs were performed using the same process, and performances and receiver operating characteristic (ROC) curves of the models were evaluated.
RESULTS: The native EGD LR model had an ROC curve area of 0.94. For external validation, the ROC curves were 0.92, 0.94, and 0.94 for the reduced Greco, hierarchy, and LR models, respectively. Pairwise comparison between models was not significant.
CONCLUSION: The LR model performed as well as RSM in generalizing the predicted sedative effect of midazolam and alfentanil during gastrointestinal endoscopies. LR may be used for generalization across patients experiencing procedures with similar stimulus intensities.
Full text links
Related Resources
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app