Clinical Trial
Comparative Study
Journal Article
Add like
Add dislike
Add to saved papers

Comparison of cyanoacrylate embolization and radiofrequency ablation for the treatment of varicose veins.

Phlebology 2019 May
OBJECTIVE: To review clinical outcomes of varicose vein patients treated with cyanoacrylate embolization and radiofrequency ablation at our institution.

METHODS: A retrospective review of patients who underwent cyanoacrylate embolization and radiofrequency ablation during a three-year period. Patient records were reviewed to assess demographics, location and severity of disease, treatment details and outcome at short- and mid-term follow-ups. Outcome parameters included treatment success and complications.

RESULTS: Between January 2014 and December 2016, 335 patients with 476 veins were treated with either cyanoacrylate embolization (n = 148) or radiofrequency ablation (n = 328) at the Vancouver General Hospital Vascular Surgery Vein Clinic. The average age of patients were 57 ± 1 years with the majority being female (78%) and an average BMI of 24.8 ± 0.5. CEAP classes were 2 (49%), 3 (26%), 4a (22%) and >4b (3%). Of the veins treated with cyanoacrylate embolization, the vein types were as follows: 76% were great saphenous vein, 16% were small saphenous vein, 5% were anterior accessory great saphenous vein and 1.4% were perforator veins. The vein types for radiofrequency ablation were 88%, 9%, 3% and 0%, respectively. The average amount of cyanoacrylate embolization delivered for great saphenous vein treatment was 1.8 ± 0.1 ml with a treatment length of 43 ± 1 cm. Subgroup comparison was done for great saphenous vein segments. Treatment success was 100% in cyanoacrylate embolization and 99% in radiofrequency ablation. Superficial phlebitis was the most common complication noted at mid-term follow-up in 5% of cyanoacrylate embolization and 16% of radiofrequency ablation treatments (P < 0.05). One patient in each group had asymptomatic proximal thrombus extension treated with anticoagulation for 2-3 weeks. Three superficial infections from glue clumps were noted in the cyanoacrylate embolization group requiring excision and drainage. Five patients in the radiofrequency ablation group had persistent numbness and one wound complications at the access site.

CONCLUSION: Cyanoacrylate embolization offers equivalent success rates with lower mid-term complication rates as radiofrequency ablation.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app