Add like
Add dislike
Add to saved papers

A self-powered photoelectrochemical glucose biosensor based on supercapacitor Co 3 O 4 -CNT hybrid on TiO 2 .

In this study, a photoelectrochemical (PEC) biosensor was constructed by depositing supercapacitor carbon nanotubes (CNT) and Co3 O4 onto the anatase TiO2 coated ITO electrodes. Herein, supercapacitor Co3 O4 was employed as a semiconductor with a band gap of ~2.07 eV, and the supercapacitor behavior of the PEC system was improved by introducing CNT into the electrode material. Furthermore, a self-empowering glucose biosensor operating at 0 V was constructed for the first time. Also, upon the formation of p-n junction, Co3 O4 was rendered electron accepting material, unlike its usual use in photocatalytic systems. Co3 O4 -CNT-anatase TiO2 semiconductor hybrid was used to reduce recombination of exited electrons, and increasing the visible light absorption. Prior to enzyme immobilization, CNT containing electrode material was modified with 1-pyrene boronic acid via π-π interactions. The enzyme immobilization was carried out through covalent esterification between the boronic acid moiety and the carbohydrate part of GOx. Enzyme immobilization way enabled the close contact between FAD and electrode material, and the electron donor FADH2 forming after the enzymatic reaction can give electrons to the photogenerated holes of Co3 O4 through CNT along with H2 O2 by enhancing the photocurrent. The obtained PEC biosensor demonstrated acceptable reproducibility and decent stability with a linear measurement range of 0-4 mM, a sensitivity of 0.3 µA mM-1 cm-2 , and lower detection limit of 0.16 µM. Thus, a self-powered biosensor was constructed by combining the PEC, and supercapacitor behavior of Co3 O4 for the first time, and the utilization of the present PEC material can be extended to the other analytes detection through photoelectrochemistry. The supercapacitor materials led to the high current at direct electron transfer potential range, and this phenomenon implies that the PEC electrode can also be used in biofuel cells to obtain high power.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app